To ensure both high performance and safety, L-ACOUSTICS
®
recommends the exclusive use of high-
quality, fully insulated speaker cables made of stranded copper wire.
In order to preserve a high damping factor it is desirable to keep loudspeaker cables as short as possible and
with a gauge offering low resistance per unit length.
The following table provides information regarding the recommended cable length versus conductor cross-section.
Two cases are possible depending on the impedance load connected to the LA4 or LA8 (8 Ω for a single SB18
enclosure, 4 Ω for two SB18 enclosures in parallel):
Table 2: Maximum cable length versus conductor cross-section for Damping Factor > 20
Cross-section
Length for 1 SB18 (8 Ω load)
Length for 2 SB18 (4 Ω load)
mm
2
SWG
AWG
m
ft
m
ft
2.5
15
13
30
100
15
50
4
13
11
50
160
25
80
6
11
9
74
240
37
120
10
9
7
120
390
60
195
According to the calculation in Table 2, a DO25/DOSUB-LA8 cable combination can be used to power two SB18 in
parallel (4 Ω load) with a damping factor still greater than 20.