KIVA SYSTEM
KIVA SB15
m
rigging manual
VERSION 1.1
KIVA-SB15
m
_RM_EN_1.1
w w w . l - a c o u s t i c s . c o m
16
Attaching KIET to KIVA
PROCEDURE D
The site angle of a
pole-mounted
KIVA enclosure is defined by its angle with the KIET. Refer to
Figure 2
to choose
the hole corresponding to the targeted site angle.
Figure 2 Angulation arm holes
EQUIPMENT
Electric screwdriver with torque selector.
13 mm hex socket.
13 mm hex key.
1.
Assemble the KIET and the pole adapter with the four M8 hex bolts and nuts provided in the package..
Use a 13 mm hex key, a 13 mm hex socket and set the torque to 5 N.m/45 in.lb
2.
Attach the two linking points at the front of the KIET to the two linking points of the enclosure.
a.
Place the KIVA enclosure with its logo on the right on a stable horizontal surface.
b.
Align the KIET linking points slightly left to the linking points of the enclosure.
c.
Slide the KIET to the right until you hear a clicking sound to secure and lock the system.
3.
Secure the enclosure angulation arm on the KIET using the hole corresponding to the targeted site angle.
a.
Remove the ball-locking pin from the KIET.
b.
Pull the spring-loaded pin to release the angulation arm from the enclosure.
c.
Position the arm in the KIET slot.
d.
Insert the pin through the KIET slot and the hole corresponding to the targeted angle.
Refer to
Figure 2 Angulation arm holes
.
4.
Verify the locking system is engaged by shaking the assembly up and down and side to side.