73
heat chamber “PURGE” cycle, removing any propane vapor.
6. During the second cycle, the blower will continue to run. The
module board will send a spark to the burner tube and then open
the control valve to release propane to burner tube.
7. Ignition attempt will be for 7 seconds.
8. Failing to ignite, board will make 2 more attempts to light and go
into a lockout.
9. After (3) attempts with no ignition, drop thermostat to lowest
setting, wait 1 minute and repeat steps 4 to 7.
10. After burner tube lights, set thermostat to desired setting.
11. To shut burner down, move thermostat to lowest setting or
“OFF”.
12. Blower will continue to run for about 2 minutes until heat is
removed from chamber.
NOTE:
Different model furnaces are used for different unit floor plans.
Each model furnace has its own
User’s Manual. The following instructions
may vary slightly from the instructions in your unit. Therefore it is very
important that you refer to the
User’s Manual provided by the furnace
manufacturer.
To Turn Appliance off:
1. Set the thermostat to lowest setting, then move lever or switch
to “OFF” position.
2. Turn off all electric power to the appliance if service is to be
performed.
External Vents
Always be sure these vents are clear of any objects like screens, or duct
tape, BEFORE ATTEMPTING TO OPERATE.
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
DO NOT operate the furnace while vehicle is in motion or
being towed.
DO NOT install screens over the vents for any reason.
Screens will become restricted and cause unsafe furnace
operation. Accessories are being marketed for RV products,
which KZRV does not recommend. For your safety, only
factory authorized parts are to be used on your furnace.