background image

 

 

Website : www.kyowa-ei.com

 

 

 

10. Dimensional drawing 

 
 

 
 

 
 
 
 
 
 
 
 
 
 
Note:

 It is the size when attaching the attached mounting band.

 

Models 

Mounting Band 

DTH-A-5 

FXB-5A 

85 

68 

60 

20 

21 

57 

DTH-A-10 

FXB-5A 

97 

75 

67 

11 

20 

21 

57 

DTH-A-20 

FXB-5A 

123 

91 

83 

21 

20 

21 

57 

DTH-A-30 

FXB-5A 

150 

108 

100 

31 

20 

21 

57 

DTH-A-50 

FXB-50A 

210 

148 

140 

51 

25 

23.5 

62 

DTH-A-100 

FXB-100A 

360 

248 

240 

101 

35 

28.5 

72 

11. Specifications 

Model 

Rated 

capacity 

Measuring Force 

(Approx.) 

Weight 

(Approx.) 

DTH-A-5 

  5 mm 

1.5 N 

30 g 

DTH-A-10 

10 mm 

2.2 N 

35 g 

DTH-A-20 

20 mm 

2.2 N 

35 g 

DTH-A-30 

30 mm 

2.2 N 

40 g 

DTH-A-50 

50 mm 

3 N 

75 g 

DTH-A-100 

100 mm 

4 N 

200 g 

Performance 
Rated Capacity 

See table below. 

Nonlinearity 

Within ±0.1%RO 

Hysteresis 

Within ±0.1%RO 

Repeatability 

0.1%RO or less 

Repeatability 

5 mV/V ±0.1% 
(DTH-A-5:±0.15%) 

Environmental Characteristics 
Safe Temperature 

-10 to 70

(Non-condensing) 

Compensated Temperature 

0 to 60

  (Non-condensing) 

Temperature Effect on Zero 

Within ±0.01%RO/

 

Temperature Effect on Output  Within ±0.01%/

 

Electrical Characteristics 
Safe Excitation 

6V AC or DC 

Recommended Excitation 

1 to 4 VDC 

Input Resistance 

350  ±1% 

Output Resistance 

350  ±1% 

Cable 

4-conductor (0.065mm

2

) vinyl shielded 

cable, 4mm diameter by 2m long, 
terminated with a connector plug 

 

(PRC03-12A10-7M) 
(Shield is not connected to the 
chassis.) 

Mechanical Properties 

Frequency Response 

DC to approx. 2Hz 

Measuring Force 

See table below. 

Weight 

See table below. (Excluding Cable) 

Degree of protection 

IP50 (IEC 60529) 

Compliance 

Directive 2011/65/EU, (EU) 2015/863 
(10 restricted substances) (RoHS) 

[NOTE] 
Products with CE Marking are compliant European RoHS Directive.   

Accessories 
Mounting Band (FXB-5A) 

1 (for DTH-A-5 to 30) (Note) 

Mounting Band (FXB-50A) 

2 (for DTH-A-50) (Note) 

Mounting Band (FXB-100A) 

2 (for DTH-A-100) (Note) 

Note:

 One Mounting Ban

d(FXB-A)

 includes the following parts.

 

Mounting Band 

Rounded machine screw (M6×12) 

Plain washers (nominal size: 6) 

Wing bolt (M4×12) 

 

Probe (X-1-DT) 

1(Note) 

Protection tube 

1(Note) 

Note:

 

It is attached to the product at delivery. 

 

Test Data Sheet 

Instruction manual 

1 (This book) 

Optional Accessories 
Extension Rods 

EB-50,100,200 

Mounting Band   

FXB-5A,10A,100A 

Replacement Probes 

X,XS,SH 

 

(A) 

(20)

(

φ

8)

 

14 

Mounting band 

1.5 

G

 

H

 

(5) 

φ

φ

E

 

φ

F

 

Probe 

X-1-DT 

M2.5 d=6 

Movable 

  length 

   

Содержание DTH-A

Страница 1: ... dial gauges the probe is made to contact the measuring point for measuring However when a measuring dynamic phenomenon that the rod may fail to respond to it on occasion So make sure before measuring that it can respond 5 5 To fix the rod to the measuring point remove the probe and fix the rod to the measuring point by using a screw M2 5 6 Connection 6 1 Connect the transducer to a measuring inst...

Страница 2: ...n rod Combination of transducer and extension rod Note If a combination of displacement transducer and extension rod different from the above is used or the direction of a displacement transducer is different from the above the rod of such a transducer may fail to respond on occasion Also note that the above combinations relate to the use of the standard probe X 1 DT Mounting Band See 10 Dimension...

Страница 3: ...ics Safe Excitation 6V AC or DC Recommended Excitation 1 to 4 VDC Input Resistance 350 1 Output Resistance 350 1 Cable 4 conductor 0 065mm2 vinyl shielded cable 4mm diameter by 2m long terminated with a connector plug PRC03 12A10 7M Shield is not connected to the chassis Mechanical Properties Frequency Response DC to approx 2Hz Measuring Force See table below Weight See table below Excluding Cable...

Страница 4: ...不平衡値は 6000 5000 10 6 ひずみ です 5 3 変位変換器に約 0 3mm の変位を加えた状態で固定してく ださい 5 4 ダイヤルゲージと同様に 測定子を測定点に接触させて 測定しますが 動的に測定するときはロッドが追従しな い場合があります 動きを確認の上 ご使用ください 5 5 測定点にロッドを固定するときは 測定子を外し M2 5 ね じで測定点に固定してください 6 接続 6 1 変換器をひずみ測定器に接続します 6 2 弊社以外のひずみ測定器を使用される場合は コネクタ プラグへの配線は下図のようになっていますので 確認 のうえ接続してください 6 3 ヒートランを 5 10 分行ってから測定を開始してください 7 換算 7 1 換算には検査成績書の校正係数を使用します 7 2 ひずみ測定器を使用する場合は 出力値がε 10 6 ひず み で表示されます 1 1...

Страница 5: ...T 注 XS 5 DT XS 2 DT は 測定対象物が球面の場合にご使用 ください 〇ローラ付測定子 SH 2 DT 〇延長ロッド 変位変換器との組合せ 注 上記以外の変位変換器と延長ロッドの組合せ または上 記以外の変位変換器取り付け方向の場合には 変位変換 器のロッドが戻らない場合があります また 上記の組合せは標準の測定子 X 1 DT の場合です 〇取付バンド 寸法は 10 外形寸法図参照 FXB 5A DTH A 5 10 20 30 用 FXB 50A DTH A 50 用 FXB 100A DTH A 100 用 型式名 φD L EB 50 4 50 EB 100 5 100 EB 200 6 200 変位変換器型式 延長ロッド型式 変位変換器 取り付け方向 DTH A 5 EB 50 EB 100 下向き 下向き DTH A 10 20 30 50 EB 50 EB 1...

Страница 6: ...000 10 6 ひずみ 0 1 DTH A 5 は 0 15 環境特性 許容温度範囲 10 70 結露しないこと 温度補償範囲 0 60 結露しないこと 零点の温度影響 0 01 RO 以内 出力の温度影響 0 01 以内 電気的特性 許容印加電圧 6V AC または DC 推奨印加電圧 1 4V AC または DC 入力抵抗 350Ω 1 出力抵抗 350Ω 1 ケーブル 0 065mm2 4 心シールドビニル 2m 外径 4mm 先端コネクタプラグ PRC03 12A10 7M シールドは本体に接続されていません 機械的特性 応答周波数範囲 DC 約 2 Hz 測定力 表参照 質量 表参照 ケーブル含まず 保護等級 IP50 JIS C0920 適合指令 RoHS指令2011 65 EU EU 2015 863 10物質 注 RoHS指令対応品は CEマークの表記付き製品に限ります ...

Отзывы: