DOs and DONʼTs

DOs and DONʼTs

DOs

DONʼTs

Operate the system under the designated 

    circumstances

Do not disassemble or open electric or 

   precision components

Power input: AC100V~230V plus or minus 10%, 50Hz/60Hz 
Temperature range: between 0 degrees C and 40 degrees  C   
(no congelation)
Relative humidity; between 0%to 80% (no condensation)
*Connecting to power source outside of the designated 
range may lead to fire. 

Safe disposition

Handle with care

When the electric parts get warm or produce 

    smoke, immediately turn off the power and 

    unplug from the power source

Storage

Handle the power plug and cord observing 

  

 following precautions

Never wipe the product and components

   with thinner or organic solvant

Donʼt mark on the product and components with pen or 

leave any printed materials in contact with their surface.

The electric components are precision instruments.

Strong shocks or continuous vibration may cause breakages 

of  its internal structure.

Take at least 30 minutes shutdown, turning off the power, 

every 2 hours.

When you use this model continually for a long time, it might 

malfunction occasionally due to heat in some circumstance.

In this case, shut down the model for about 30 minutes and 

restart.

Risk of shock.

Do not pour or spill water or liquid detergent over the 

electric components, power cable and power plug.

Running the system while the electric components are wet 

may create a shock hazard or a risk of fire.

Do not put the product close to fire. It may lead to discolor-

ation or deformation of the product as well as short circuit, 

creating a risk of fire.

Do not give shocks

Do not wet the electric components

Do not handle the power plug with wet hands

No fire

Do not run the system continuously over 

   2 hours

Ink marks on the soft surface wonʼt be 

   removable

To avoid short circuit, do not run the simulator set above a 
power receptacle.

Risk of fire. Contact your distributor or the manufacturer for 
repair.

Handle the model carefully, like an actual patient. Excessive 
force or impact may damage the product or result in 
problems.
The materials for the models are special compositions of soft 
resin. Please handle them with utmost care at all times.
For cleaning, wipe the model with water or soap water. If stain 
persists, wipe with alcohol and place talcum powder on the 
breast skin after dried.

Store the simulator at room temperature, away from heat, 
moisture and direct sunlight.
Storage under the temperature above 50 degrees C may 
reduce the performance quality of the simulator. 

1. Clean the head of the plug periodically.
2. Plug in the plug to the outlet firmly to the end.
3. Always hold the plug when unplugging. Do not pull the cable.
4. Do not force to bend, twist the cable and avoid scratching
   or cutting on it.
Failing to follow the above precautions can result in damage in 
the plug and the cable, constituting risk of fire or shock. 

Do not open up or disassemble the housing for electric parts 
or precision components.
Refrain from opening up any lids, caps or covers for such 
area, and never run the system while any of such covers are 
open.
*Never disassembling the electric components, power plug 
and cable as it may create a risk of fire, shock or injury. 
Contact your distributor or the manufacturer for repair.

Содержание Physiko

Страница 1: ...Physical Assessmemt Model Physiko Instruction Manual ...

Страница 2: ...Physical Assessment Simulator ...

Страница 3: ... P 3 P 5 P 7 P 8 P 9 P 10 P 11 P 12 P 13 P 14 P 15 P 16 P 20 P 21 P 22 P 23 P 24 P 25 必ずお読みください This product is designed for training in medical education Do not use it for other purposes Read Note in use before use of model If you have any questions contact Kyoto Kagaku Contact address is printed on back cover Handle the model carefully Excessive force or physical impact may damage the product or...

Страница 4: ...ny cases for each procedure which facilitates learning of the features for each case Physiko facilitates learning of the basic procedure for physical assessment comprehensively interfacing with PC Physiko facilitates practice for Pupil reflex BP measurement Right Arm Pulsation Carotid artery Radical artery Auscultation Lung and Heart sound and ECG Features System Configuration Physiko consists of ...

Страница 5: ...Use the Sphygmomanometer provided in kit Connect power cable from PC to outlet in Terminal box It is possible to connect the cable to ECG to the Electrocardiographic Monitor you have Pay attention not to make an impact on the PC or the Terminal box Electrocardiographic monitor may not be able to connect to the Terminal box Figure to connect each device USB 96 pin teminal cable to ECG ECG lead Term...

Страница 6: ...x Connect each cable to suitable terminal carefully according to the figure on side of Terminal Box Do not use the outlet in Terminal Box for another electric device since it is designed for the PC provided in kit How to connect each device 4 to ECG Monitor you have to ECG lead to ECG lead to Sphygmomanometer to Sphygmomanometer to power of PC to power of PC to outlet to outlet to USB teminal of P...

Страница 7: ...ts up when every connection is made correctly and the power of PC is turned on Refer to page 9 regarding how to adjust these adjusters Terminal side of PC The layout of terminal is subject to change according to the model of PC However the way of connection is not changed USB USB How to connect each device 5 to Terminal Box to Mouse You may connect to any USB connectors of the Terminal side of PC ...

Страница 8: ...Physical Assessment Model Physiko 6 How to use the software ...

Страница 9: ...enu is shown If the message The USB BOX is not connected shows on the display check the connection of each device How to use software Start Up PC Top Menu Top Menu Start Up PC To Shut down the software and turn off PC To the individual examination skills training mode P 22 P 21 To patient cases editor mode P 14 20 To the patient cases mode P 10 To system configuration to adjust P 8 9 7 ...

Страница 10: ...age is Top Manu Return to 8 The window on left can be opened by clicking the Volume Set icon Adjust the volume suitably as you need 1 Move the slider left to right to adjust each volume The volume becomes higher by moving it to right It becomes lower by moving it to left 2 Click Adopt icon after setting each volume 3 Click Reset icon to make the status before shipment 4 Click Cancel icon to make t...

Страница 11: ...le sign when you speak into the microphone and Inaudible sign when you don t speak When turning knob counterclockwise it becomes sensitive to even silent voice and when turning clockwise it becomes insensitive How to use software System Confiruration How to adjust the pupils light sensors How to adjust listening volume 9 Adjust the pupils light sensors according to the brightness in the room in or...

Страница 12: ...Patient case editor on Top menu when you create new patient and learn with that When you put cursor on the bar on left side of the screen the data of its patient is shown on the right side of the screen When you click the bar of the patient data it changes to the screen for the physical assessment session It takes a little time to change screen Regarding how to learn the patient cases refer to pag...

Страница 13: ...or or click the number you change and input by keyboard You cannot input greater number to S4 than S5 s How to use software Patient cases editor Creating patient case How to input letter by keyboard In the case of Japanese version of PC Shift 半角 全角 漢字 11 Alphabet input mode is set usually If it is not switch to alphabet mode by following instruction to Alphabet input mode ...

Страница 14: ... you named existing filename the dialogue is shown You may change the filename to resave or overwrite When you delete created file click Save or Call data After the window is shown like the left click the filename you delete like and click Delete icon How to save the file How to delete the file How to use software Patient cases editor 12 ...

Страница 15: ...ose If there is unsaved file the window below will be shown Regarding how to save the file refer to page 12 Click Yes if you don t save the file and execute another one Click No if you save the file and click Execution after saving the file Regarding how to save the file refer to page 12 Click the Execution bar on the left when you execute Created file or Opened file If you execute Unsaved file th...

Страница 16: ...se up to three files Choose the executing time according to following order Click the file in Continuous execution pattern box you choose the executing time for Next you click Executing time and choose one from five options of executing time you need in pull down menu Repeat task to choose proper Executing time for every file you chose If you don t choose Executing time for a file it will be one m...

Страница 17: ...lick Unlock the file is unlocked from the choice Click Execution after finishing configuration It takes a time for this system to transfer the data to the terminal box from PC when you choose next file in the continuous execution Continuous execution How to use software Patient cases editor Changing the order of files to execute Unlocking the chosen file Execution 15 ...

Страница 18: ...ration for learning course When you go into Learning course the screen below is shown first Choose skill you would like to learn and click it There are The patient overview and Details of the findings screens in each learning course You can switch the screen by clicking the icon on top left in the screen You can retrun to Top Menu 16 ...

Страница 19: ...Details of findings screen You can check what finding is by pressing this icon The example screen is for Pupil reflex The figure of icon is different in each skill There is Case explanation icon on bottom right in each Details of the findings screen You can check what case is by pressing this icon It is blank in Patient case editor 17 ...

Страница 20: ...t screen you can choose ECG wave by clicking ECG display surrounded in line on left figure You can choose Indicate or Hide in Electrode status on ECG detail screen You can adjust volume by click by Volume Setting icon in some cases P 8 Refer to Volume setting Electrode Status Hide Electrode Status Indicate 18 ...

Страница 21: ... changed to stethoscope icon Make a sound from speakers in PC by clicking that icon When you stop making a sound click the other area except the sound wave You can change to anterior or posterior by clicking the icon encircled by red dash line If the quality of sound from PC speaker is not good enough we recommend you use the external speaker with built in amplifier EX In Heart sound the cursor wi...

Страница 22: ...e Patient cases Basic operation for learning course Notes in Blood pressure measurement During cuff application for BP measurement if The cuff is not appropriately applied message appears see left refer to the diagram below to insure that it is correctly done 20 Right arm ...

Страница 23: ...een except Blood pressure case When you click this icon the pull down cases appear Choose a case to practice You can set the value of S1 S2 S5 in Blood Pressure Measurement When you click BP measurement icon under the screen Dialogue is shown and you can set each value by clicking and icon beside numbers その他の操作方法につき How to use software Skills Training Basic operation for Skills training Choice of ...

Страница 24: ...ight in each screen to go to Top Menu Next when you click Quit on bottom right the window below is shown Click Yes to quit The program ends and PC shut down automatically How to quit software How to use software How to quit 22 ...

Страница 25: ... power or weaken the pulse setting to cool the device Recommend setting of the pulse strength is marked as shown in above photo Pulse Strength Adjustment Adjust the pulse by turning knob clockwise or counter clockwise Strong Mark Recommended setting Weak Turn clockwise to raise pulse strength and turn counter clockwise to lower pulse strength Turning the knob fully left will make the pulse barely ...

Страница 26: ... appeared on the screen Q The screen was changed to OS mode or the application program was frozen PC is driven by battery without connecting to the power 115V Connect PC power cable to outlet of Terminal Box A PC needs to be restarted Click Menu A icon at the bottom of screen Choose Restart PC bar on the opened menu and click OK The screen was changed to OS mode The application program was frozen ...

Страница 27: ... PC is making small sound wait for PC to be silent and press the power switch Caution Don t shut down the PC in this manner on a regular basis or it may possibly break This is the only way to shut down the PC when the application software is frozen abnormally Q A A In this case keep Mannequin at over 50 degree F for awhile and operate the system after it returns to room temperature Q A ECG sensor ...

Страница 28: ...product as well as short circuit creating a risk of fire Do not give shocks Do not wet the electric components Do not handle the power plug with wet hands No fire Do not run the system continuously over 2 hours Ink marks on the soft surface wonʼt be removable To avoid short circuit do not run the simulator set above a power receptacle Risk of fire Contact your distributor or the manufacturer for re...

Страница 29: ......

Отзывы: