background image

INSTRUCTION MANUAL

KEW 8146/8147/8148

LEAKAGE CLAMP SENSOR 

Series

KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD.,

TOKYO, JAPAN

KEW8146

KEW8147

KEW8148

LEAKAGE CLAMP SENSOR

1. Safety warnings

This  instrument  has  been  designed,  manufactured  and 

tested according to IEC 61010: Safety requirements for 

Electronic  Measuring  apparatus,  and  delivered  in  the 

best  condition  after  passing  quality  control  tests.  This 

instruction  manual  contains  warnings  and  safety  rules 

which  have  to  be  observed  by  the  user  to  ensure  safe 

operation  of  the  instrument  and  to  maintain  it  in  safe 

condition.  Therefore,  read  through  these  operating 

instructions before using the instrument.

#

 WARNING

●   Read  through  and  understand  instructions  contained 

in this manual before using the instrument.

●  Keep  the  manual  at  hand  to  enable  quick  reference 

whenever necessary.

●  The  instrument  is  to  be  used  only  in  its  intended 

applications.

The  operating  instructions  described  in  the  manual 

must be observed.

●  Understand  and  follow  all  the  safety  instructions 

contained in the manual.

It is essential that the above instructions are adhered 

to. Failure to follow the above instructions may cause 

injury and or instrument damage.

The symbol 

#

 indicated on the instrument, means that 

the user must refer to the related parts in the manual 

for  safe  operation  of  the  instrument.  It  is  essential  to 

read the instructions wherever the 

#

 symbol appears 

in the manual. 

#

 

DANGER

 is reserved for conditions and actions that 

are likely to cause serious or fatal injury.

#

 

WARNING

  is  reserved  for  conditions  and  actions 

that can cause serious or fatal Injury.

#

 

CAUTION 

is reserved for conditions and actions that 

can cause minor injury or instrument damage.

Safety symbols

Incoming wire

O:

Device which is  

    not directly 

    connected to the 

    mains power supply

Socket

Interior wiring

○Measurement Category:

  To  ensure  safe  operation  of  measuring  instruments, 

IEC  61010  establishes  safety  standards  for  various 

electrical  environments,  categorized  as  O  to  CAT  IV, 

and  called  measurement  categories.  Higher-numbered 

categories  correspond  to  electrical  environments  with 

greater  momentary  energy,  so  a  measuring  instrument 

designed  for  CAT  III  environments  can  endure  greater 

momentary energy than one designed for CAT II.

:  Circuits which are not directly connected to the 

mains power supply.

CAT II  :  Electrical circuits of equipment connected to an 

AC electrical outlet by a power cord.

CAT III  :  Primary  electrical  circuits  of  the  equipment 

connected directly to the distribution panel, and 

feeders from the distribution panel to outlets.

CAT IV  :  The  circuit  from  the  service  drop  to  the  service 

entrance,  and  to  the  power  meter  and  primary 

over-current  protection  device  (distribution 

panel).

 2. Features

● Clamp sensor for AC leakage current measurement.

●  Can measure up to:

    KEW 8146:30A

    KEW 8147:70A

    KEW 8148:100A

● Designed to international safety standard IEC61010-2-032

    

CAT. Ⅲ  Pollution Degree 2

 3. Instrument layout

 4. DIN Plug pin assignment

3: GND pin

5: Output signal pin

6: Sensor Signal pin

 ( Resistance between 3Pin and 6Pin:

    8146 : 47kΩ 8147 : 8.2kΩ 8148 : 30kΩ)

1, 2 and 4 : No use

* Lower  figure  shows  the  pin  assignment  seeing  the  Clamp 

sensor  from  output  connector  part.  The  figure  of  the  pin 

assignment  of  connection  terminal  is  symmetrical  to  lower 

figure.

5

3

1

2

4

6

Transform Jaws

Trigger

Cable

Output connector

Barrier

 5. Operating instructions 

#

 DANGER

●  Never  make  measurement  on  a  circuit  in  which  the 

electrical potential exceeds AC300V in order to avoid 

possible shock hazard.

●  The transformer jaws are made of metal and their tips 

are  not  completely  insulated.  Be  especially  careful 

about  the  possible  shorting  where  the  measured 

object has exposed metal parts.

.

#

 CAUTION

●  Take  sufficient  care  to  avoid  shock,  vibration  or 

excessive  force  when  handling  the  instrument. 

Otherwise, precisely adjusted transformer jaws will be 

damaged.

●  When transformer jaws do not fully close, never try to 

close them by force, but make them free to move and 

try  again.  If  a  foreign  substance  is  stuck  in  the  jaw 

tips, remove it. 

●  When  making  current  measurements,  keep  the 

transformer jaws fully closed.

Otherwise, accurate measurements cannot be taken.

●  Hold  the  inserting  part  (except  for  the  cable)  and 

disconnect the Output connector from the measuring 

instrument so as not to cause a break in the cord.

●  When  measuring  current  which  pulse  element  is 

superposed,  differences  of  the  indicated  value  may 

be caused between ranges, if the peak value exceeds 

the measurement range to a large extent. In this case, 

the  reading  at  the  bigger  range  should  be  taken  as  a 

right  value.  Sensitive  transformer  jaws  are  used  for 

Leakage clamp meter. Because of the characteristics 

of  transformer  jaws,  which  can  be  opened  and 

closed,  it  is  impossible  to  eliminate  the  interference 

of  external  magnetic  field  completely.  If  there  is  a 

presence of strong magnetic field, use the instrument 

at a distance as far as possible from it. Following are 

the typical things generating magnetic field.

     ・Conductor fed large current

     ・Motor

     ・Equipment which has magnet

     ・Integrating wattmeter

DISTRIBUTOR

#

Refer to the instructions in the manual.

Indicates a Instrument with double or reinforced insulation

Indicates  that  this  instrument  can  clamp  on  live  bare 

conductors  when  the  voltage  to  be  tested  is  below 

Circuit - Ground-to-Earth voltage against the indicated 

Measurement Category.

Indicates AC

MINI DIN 6PIN

50MΩ or greater at 1000V

  between Jaw and enclosure

  between enclosure and output terminal

  between Jaw and output terminal

Model
Rated voltage
Output voltage

Measuring range
Accuracy
(Input: sine wave)

Temperature & humidity range
(Guaranteed accuracy)
Operating temperature range
Storage temperature range
Maximum permissible input
Output
impedance
Location for use
Applicable
standards

Withstand 
voltage

Insulation 
resistance

Conductor Size
Dimension
Cable length
Output terminal
Weight
Accessories

Option

 6. Specifications

   23±5℃, relative humidity: 85% or less (no condensation)

   0〜50℃, relative humidity: 85% or less (no condensation)

-20〜60℃, relative humidity: 85% or less (no condensation)

Altitude up to 2000m, Indoors

IEC 61010-1, IEC 61010-2-032

  Measurement CAT. 

 (300Vrms) 

  Pollution degree 2

IEC 61326-1 (EMC), EN50581 (Environmental standard)

Approx. 2m

Instruction manual 

Cable marker

Approx. 510g

Approx. 240g

Approx. 150g

186(L) × 129(W) × 53(D)mm

128(L) × 81(W) × 36(D)mm

100(L) × 60(W) × 26(D)mm

Approx.68mm in diameter (max.)

Approx.40mm in diameter (max.)

Approx.24mm in diameter (max.)

AC3470Vrms (50/60Hz)for 5 sec. 

  between Jaw and enclosure

  between enclosure and output terminal

  between Jaw and output terminal

Approx. 60Ω

Approx. 100Ω

Approx. 90Ω

AC100Arms continuous (50/60Hz)

AC70Arms continuous (50/60Hz)

AC30Arms continuous(50/60Hz)

0A〜80A

    

±1.0%rdg±0.1mV (50/60Hz)

    

±2.0%rdg±0.2mV (40〜1kHz)

80A〜100A

    

±5.0%rdg (50/60Hz)

    

±10.0%rdg (45〜1kHz)

0A〜15A

    

±1.0%rdg±0.1mV (50/60Hz)

    

±2.0%rdg±0.2mV (40〜1kHz)

15A〜30A

    

±5.0%rdg(50/60Hz)

    

±10.0%rdg(45〜1kHz)

0A〜40A

    

±1.0%rdg±0.1mV (50/60Hz)

    

±2.0%rdg±0.2mV (40〜1kHz)

40A〜70A

    

±5.0%rdg (50/60Hz)

    

±10.0%rdg (45〜1kHz) 

AC0 〜 100A

AC0 〜 70A

AC0 〜 30A

AC0〜5000mV

(50mV/A)

AC0〜3500mV

(50mV/A)

AC0〜1500mV

(50mV/A)

AC100Arms(141.4Apeak)

AC70Arms(99.0Apeak)

AC30Arms(42.4Apeak)

KEW 8148

KEW 8147

KEW 8146

MODEL 7146(Banana Φ4 adjuster plug)

MODEL 7185(Extension cable)

www.

.com

[email protected]

1.800.561.8187

Отзывы: