background image

1.Safety warnings

This  instrument  has  been  designed,  manufactured  and  tested

according  to  IEC  61010-1:  Safety  requirements  for  Electronic

Measuring  apparatus,  and  delivered  in  the  best  condition  after

passed  the  inspection.  This  instruction  manual  contains  warnings

and safety rules which must be observed by the user to ensure safe

operation of the instrument and retain it in safe condition. Therefore,

read  through  these  operating  instructions  before  using  the

instrument.

WARNING

¡

Read  through  and  understand  the  instructions  contained  in  this

manual before using the instrument.

¡

Keep  the  manual  at  hand  to  enable  quick  reference  whenever

necessary.

¡

The instrument is to be used only in its intended applications.

¡

Understand  and  follow  all  the  safety  instructions  contained  in the

manual.

¡

It

is  essential  that  the  above  instructions  are  adhered  to  failure  to

follow the above instructions may cause injury, instrument damage

and/or damage to equipment under test.

The symbol

indicated on the instrument, means that the user must

refer  to  the  related  parts  in  the  manual  for  safe  operation  of  the

instrument.  It  is  essential  to  read  the  instructions  wherever  the 

symbol appears in the manual.

DANGER  

:is reserved for conditions and actions that are likely

to cause serious or fatal injury.

WARNING

:is reserved for conditions and actions that can cause

serious or fatal injury.

AUTION    

:is  reserved  for  conditions  and  actions  that  can

cause injury or instrument damage.

DANGER

¡

Never  make  measurement  on  a  circuit  in  which  the  electrical

potential exceeds AC/DC600V(Measurement CAT. III 600V).

¡

Do  not  attempt  to  make  measurement  in  the  presence  of

flammable  gasses.  Otherwise,  the  use  of  the  instrument  may

cause sparking, which can lead to an explosion.

¡

Never attempt to use the instrument if it

'

s surface or your hand are wet.

¡

Be careful not to short-circuit the power line with the metal part of

the  test  leads  when  measuring  a  voltage.  It  may  cause  personal

injury.

¡

Do not exceed the maximum allowable input of any measuring range.

¡

Never open the Battery cover during a measurement.

― 1 ―

Содержание KEW 3021

Страница 1: ...Instruction manual INSULATION CONTINUITY TESTER KEW 3021 3022 3023 KYORITSU ELECTRICAL INSTRUMENTS WORKS LTD ...

Страница 2: ... 6 4 Output voltage characteristics 13 6 5 Measurement of resistance Continuity check 14 6 6 Backlight function 15 6 7 Auto power off 15 7 Functions keys 16 7 1 Comparator function 16 7 2 Memory save function 17 8 Fuse Battery replacement 18 8 1 Battery replacement 18 8 2 Fuse replacement 18 9 Notes on Housing case and accessories 19 9 1 Case lid 19 9 2 Neck strap and Cord case 19 9 3 Test prods a...

Страница 3: ...age to equipment under test The symbol indicated on the instrument means that the user must refer to the related parts in the manual for safe operation of the instrument It is essential to read the instructions wherever the symbol appears in the manual DANGER is reserved for conditions and actions that are likely to cause serious or fatal injury WARNING is reserved for conditions and actions that ...

Страница 4: ...rument is wet Ensure that the test leads are firmly inserted into the terminal Set the Range selector switch to OFF position when opening the Battery cover for battery replacement CAUTION Always set the Range selector switch to the appropriate position before making measurement Set the Range selector switch to OFF position after use and remove the test leads The instrument consume small current at...

Страница 5: ...value is held for about 5 sec after insulation resistance measurement of the Test button is released Backlight function to facilitate work at night or dimly lit locations Bar graph to indicate measured results Max 99 data can be saved to the internal memory at the insulation resistance range Visible and audible warning or is indicated and buzzer sounds when the measured insulation resistance excee...

Страница 6: ...1001 2000MΩ 200 1 2000MΩ 40 0 2000MΩ 20 01 200 0MΩ 0 0 099MΩ 0 0 099MΩ 0 0 099MΩ 2 rdg 6dgt 5 rdg 6dgt Within 6dgt 50MΩ 5MΩ 5MΩ 0 100 200 0MΩ 0 100 40 0MΩ 0 100 20 0MΩ 0 5MΩ 0 25MΩ 0 125MΩ 500V 250V 125V 0 4 40 200MΩ Nominal voltage Auto Range Open circuit voltage Short circuit current Nominal test current 1st effective measurement range Center scale range Accuracy 2nd effective measurement range ...

Страница 7: ... 0MΩ 0 5MΩ 0 25MΩ 0 1MΩ 500V 250V 100V 0 4 40 200MΩ Operating error Operating error B is an error obtained under the nominal operating conditions and calculated with the intrinsic error A which is an error of the instrument used and the error En due to variations According to IEC61557 the maximum operating error should be within 30 B A 1 15 E1 2 E2 2 E3 2 A Intrinsic error B Operating error E1 Var...

Страница 8: ...ical circuit and the enclosure Overload protection The instrument operates properly after each of the voltage shown in the table below is applied for 10 sec 20 600V 3 rdg 6dgt Within 6dgt Measured voltage Accuracy Accuracy at 0 Auto range Open circuit voltage DC Short circuit current Measuring range to keep operating error tolerance Outside of the measuring range to keep operating error tolerance ...

Страница 9: ...o less than 320 Dimension approx 105 L 158 W 70 D mm Weight approx 600g including batteries Power source R6P or LR6 size AA x 6pcs Nominal power 2 7VA Accessories MODEL7103 Test lead with remote control switch 1 set MODEL7161 test bar 1 pce MODEL7131 Safety alligator clip 1 pce MODEL8017 Extension prod 1 pce Neck strap 1 pce Cord cas 1 pce R6P SUM 3 size AA 6 pcs Instruction manual 1 pce Optional ...

Страница 10: ...probe Standard prod MODEL8072 Probe connector Safety alligator clip MODEL7131 Range selector switch MEM key UP key 0ΩADJ key Backlight key Display Test lead with remote control switch MODEL7103 Remote control switch Earth code Test bar MODEL7161 Extension prod MODEL8017 22 Fig 2 Instrument layout KEW3022 ...

Страница 11: ...acing the fuse In this case send the instrument to your local KYORITSU distributor for repair DANGER When the Test button or the Remote control switch is pressed while the Range selector switch set to an insulation resistance range take care not to touch the tip of the Test probe where a high voltage is present in order to avoid possible shock hazard Test lead and fuse must be inspected prior to m...

Страница 12: ...le electrical shock hazard Voltage cannot be measured if a break is present on the fuse Never make measurement on a circuit in which the electrical potential exceeds AC DC600V in order to avoid possible shock hazard Refer to 3 Specification AC voltage measurement When testing installation that has a large current capacity such as a power line be sure to make measurement on the secondary side of a ...

Страница 13: ...NGER When the Test button or Remote control switch is pressed with the Range selector switch set to an insulation resistance range position take care not to touch the tip of the test probe or the circuit under test where a high voltage is present in order to avoid possible shock hazard Do not make measurement with the Battery cover removed CAUTION Ensure that the circuit under test is de energized...

Страница 14: ...witch to the OFF position or turn the Remote control switch off with the test lead connected Discharge can be monitored by the LIVE LED and mark 2 Connect the Earth probe to the earth terminal of the circuit under test If the circuit is not earthed connect the Earth probe to any appropriate conductor 3 Connect the Line probe to the circuit under test and press the Test button or Remote control swi...

Страница 15: ...esent at the tip of a probe Attention should be paid to avoid possible shock hazard 6 4 Output voltage characteristics This instrument conforms to IEC61557 This standard defines that the nominal current shall be at least 1mA and the lower limit of the insulation resistance maintaining the nominal voltage at the measurement terminal See the graph below This value is calculated by dividing the nomin...

Страница 16: ...lead or fuse in order to display the resistance of the equipment under test only Setting 1 Set the Range selector switch to theΩ Continuity position 2 Short the test leads LINE red and EARTH black 3 Press the Zero Ω ADJ key with the Test button locked or with the Remote control switch pressed Then mark is lit up and a value of 0 00 Ω is displayed on the LCD This value is saved in the memory of the...

Страница 17: ...and EARTH black are shorted Change the connection of LINE red and EARTH black when measuring the voltage with the switched polarities The measurement result at the resistance function may be effected by the impedance or transient current in the operating circuit which is connected in parallel to the instrument 6 6 Backlight function To facilitate working in dimly lit situations a backlight functio...

Страница 18: ...0V range 2 Press the UP or DOWN key to select or and then press the key Select to sound the when the measured value exceeds the pre set value Select to sound the when the measured value is under the pre set value 3 The number displayed at the lower left on the LCD starts flickering Press the UP or DOWN key to select the reference value and press the key 4 The message and the set value are displaye...

Страница 19: ...ta 1 Set the Range selector switch to any desired Insulation resistance range and press the key 2 Press the UP or DOWN key to switch the memory number The measured voltage and value are displayed on the LCD Deleting all memory data 1 To delete all memory rotate the Range selector switch from OFF to Ω CONTINUITY position with the key pressed down Then release the key 2 The message clr is displayed ...

Страница 20: ...he test probe from the instrument 2 Open the battery compartment cover by unscrewing the metal captive screw to reveal battery compartment 3 Always replace all six batteries with new ones at the same time 4 Screw the battery compartment lid back on before using the instrument 8 2 Fuse Replacement 1 Disconnect the test probe from the instrument 2 Open the battery compartment cover by unscrewing the...

Страница 21: ... 2 Turn it 180 degrees Put the Case lid under the Housing case 3 Hook it on to the Housing case 9 2 Neck strap and Cord case This instrument is equipped with a strap to suspend from the neck to allow both hands to be used freely for easy and safe operation 19 9 Notes on Housing case and accessories Fig 14 Fig 15 ...

Страница 22: ...rod Used for ordinary measurement Attached to the Line probe at the time of purchase MODEL8017 Extension probe Used in difficult to reach situations MODEL8016 Pickle prod Optional Used to hook the probe on a conductor 2 How to replace Test prod To remove the Test prod turn the cap of LINE probe counterclockwise Insert the threaded end of another prod into the hexagonal hole on the probe cap as sho...

Страница 23: ...nic solvent such as benzene acetone etc 10 Cleaning of the instrument If this tester should fail to operate correctly return it to your nearest distributors stating the exact nature of the fault Before returning the instrument make sure that a Operating instructions have been followed b Test Leads have been inspected c Fuse has been checked d Battery has been checked e The unit is returned with al...

Страница 24: ...U ELECTRICAL INSTRUMENTS WORKS LTD No 5 20 Nakane 2 chome Meguro ku Tokyo 152 0031 Japan Phone 81 3 3723 0131 Fax 81 3 3723 0152 URL http www kew ltd co jp E mail info kew ltd co jp Factories Uwajima Ehime 04 12 92 1635A ...

Отзывы: