![KYOKUTOH CWDS-01 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/kyokutoh/cwds-01/cwds-01_manual_2017062004.webp)
Water Draining System – CWDS-01 -
- 3 -
Make sure the frame is firmly secured before using.
Failure to properly secure the frame during operation
may cause the product to operate abnormally.
It may cause failures or accidents.
Caution
Install the base of the device perpendicular to the floor.
Installing it at an angle will have an impact on the use
effectiveness.
Regularly inspect the body of the product to check for water
or air leaks.
Such leaks can have an impact on use effectiveness
and may cause damage to other facilities.
2. Performance parameters:
Model
CWDS-01
External dimensions
336W×275D×133H
Atmospheric pressure
0.5 - 0.8
Mounting holes
L200 x H255 (4-M8)
Effective mounting area
L240 x H290 mm
Voltage
DC24V
Power
10 W
Rated current
0.5 A
Applicable welding gun
C type gun / X type gun
*After reading this instruction manual, keep it in a place where the operators can read
it at any time.
!