![KYOKUTOH CWDS-01 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kyokutoh/cwds-01/cwds-01_manual_2017062010.webp)
Water Draining System – CWDS-01 -
- 9 -
10. Elimination of failures
Problems and countermeasures
Problem
Cause
Countermeasure
There is a large
amount of
residual water
during the tip
replacement.
When the water draining system
operates, the inflow and outflow of water
is not being shut off by the water
inflow/outflow valve which controls the
shutoff / connection of the welding gun
conduit.
Check if there are any
abnormalities with the solenoid
valve controlling the welding gun
conduit and if the solenoid valve is
functioning to shut off the
inflow/outflow of water.
The residual water and welding gun
conduit is not correctly connected.
Check the connection between the
residual water and welding gun
conduit.
The check valve assembly is damaged.
Replace the check valve assembly.
The water tank is damaged.
Replace the water tank.
The solenoid valve assembly is damaged.
Replace the solenoid valve
assembly.
The water draining system does not
respond.
Sequentially check the air sources,
the power supply, and the electrical
routes.
11. Maintenance
No.
Maintenance item
Period
1
Check for water leaks at the joints.
3 months
2
Check the amount of water during tip replacement.
6 months
12. List of supplies
No.
Name
Model
Quantity Remarks
1
Check valve
CW-WG-RB-V1-DXFZ
1
2
Solenoid valve
CW-WG-RB-V1-DCFZ
1
3
Switching valve
CW-WG-RB-V1-JZFZ
1
4
Intermediate relay
(Izumi)
RJ2S-CLD-D24
(with socket)
2
5
Cylinder
CDQ2B50-20DZ-M9BA
1
6
Water tank
CW-WG-RB-V1-02
1