10
8. Troubleshooting
■
Suction is poor
1. Check the air pressure. (Recommended: 0.5 MPa.)
2. If the recommended air pressure has been confirmed, check whether the source pipe and the
CVC main unit are connected by a single pipe. When doing so, also check the hose diameter
(Ø10 or more).
※
If the pipe branches midway, it will not provide a suction power of 0.5 MPa, and the suction
power will be insufficient.
3. If the hose is bent at an acute angle, the product may not be able to demonstrate its proper
performance.
It may also cause a fault, so use the hose with a moderate curvature (R150 or less).
Furthermore, check that chips have not built up in the chip receiving section (DB-01).
9. Supplement
Required specs for the solenoid valve
→
One with a Cv value of 1.0 or more
Recommended solenoid valve type
→
SMC: VP342-5G1-02A
Diameter for the hose from the solenoid valve to the CVC
→
Ø10 or more
Diameter for the hose from the CVC to the dust box
→
Ø32 (Inner diameter)
Содержание CVC4
Страница 14: ...12 MEMO...