7812 EAST ACOMA DRIVE
SCOTTSDALE, AZ 85260 USA
480/951-6330 • 800/544-6466
FAX: 480/951-6329
www.kyocerasolar.com
e-mail: [email protected]
Specifications subject to change without notice.
LYNCOM MODEL N25T
PV SYSTEM LIGHTING CONTROLLER
Te m p e r a t u re Setpoints
•
High Te m p e r a t u re Shutdown:
Disconnect PV:
7 0 ° C
Disconnect Load:
8 0 ° C
Reconnect PV:
6 0 ° C
Reconnect Load:
5 0 ° C
•
Operating Te m p e r a t u re Range:
-40°C to +80°C
•
Te m p e r a t u re Compensation Coeff i c i e n t :
- 4 m V / C e l l / C °
•
Cold Te m p e r a t u re Load Cutoff :
- 3 0 ° C
•
Reconnect of Cold Te m p e r a t u re Load Cutoff :
- 2 0 ° C
C o n t rol Setpoints
S e a l e d
F l o o d e d
B a t t e ry
B a t t e ry
•
High Battery Voltage System
Shutdown (8 seconds):
15.5 V
15.5 V
•
Reset For High Voltage Shutdown (I n s t a n t l y):
14.5 V
14.5 V
•
B a t t e ry Equalization:
–
15.3 V
•
Regulation Vo l t a g e :
14.1 V
14.4 V
•
B a t t e ry LVD Voltage (32 seconds):
11.3 V
11.4 V
•
Load Reconnect After Low Voltage
Disconnect (LVD) ( I n s t a n t l y ):
12.8 V
13.0 V
•
Automatic equalization:
–
14 days
•
Equalization can be triggered (32 seconds):
–
V < 1 1 . 4 V
(24V set points are twice the 12V values)
M i c ro p rocessor Sampling Period
•
PV Voltage Sampling:
8 seconds
•
B a t t e ry Voltage Sampling:
Constantly
•
Te m p e r a t u re Sampling:
3 seconds
•
Load Current Sampling
After Over- C u rrent Sampling:
3 - 6 seconds
Other Specifications
(All ratings at 25°C)
•
Weight:
14 oz. (.4 kg)
•
D i m e n s i o n s :
6.3 x 5.3 x 1.8 in. (16.0 x 13.46 x 4.57 cm)
•
Voltage Drop PV/Battery :
0.25 Volts
•
Load Short Circuit Rating:
30 Amps