background image

      

8

 

ERROR CODE-REASON AND SOLUTION

All information will be showed as code or “Error’, the following are all codes and 

corresponding solutions.

Code Cause

Corrective measure

204

Calculation error

Switch on/off the device several times and 

measure again.

220

Battery low

Charge the device

255

Received signal is too 
weak

Improve the reflective surface.  (Use target 

plate or white paper)

256

Received signal is too 
strong

Improve the reflective surface.  (Use target 

plate or white paper)

261

Out of measuring range

Measure within the appropriate range.

500

Read error

Switch on/off the device several times and 

measure again.

“ 

WARNING

  To reduce the risk of injury, user must read instruction manual ”

  

Содержание LDM-410

Страница 1: ...LDM 410 69800933 00 STD 10 21 ...

Страница 2: ...limited to telescopes or transits to view the laser beam will increase eye hazard This laser distance measure has a built in laser light The laser is a Class II and emits output power of a maximum 1mW and 630 670nm wavelengths These lasers do not normally present an optical hazard However do not stare at the beam as this can cause flash blindness The following label is on your laser measuring tool...

Страница 3: ...ser device in any way This may result in a dangerous exposure to laser radiation Do not attempt to repair or disassemble the laser distance measure If unqualified persons attempt to repair this product serious injury may occur Any repair required on this laser product should be performed only by authorized service personnel Do not operate the tool in combustible areas such as in the presence of fl...

Страница 4: ...3 1 2 3 5 4 9 8 6 7 ...

Страница 5: ... measurement range 0 40 m Wheel measurement accuracy 1 Laser class Class II Laser type 630 670 nm 1mW Measuring unit Meter Battery Li Ion built in Dimensions 100 37 24mm Weight 63g 1 The measurable range varies depending on the brightness of surrounding area and how well the laser light is reflected from the surface of the measuring object 2 The deviation of the measurement can be up to 3 0 5 0mm ...

Страница 6: ... a long time unplug the charger SWITCH Press On Off button for 1 second to turn on the device The laser indicator flashes on the display When no button is pressed for about 30 seconds the laser beam is automatically turned off and then the device is automatically turned off after about 3 minutes To turn off the device press On Off button for 1 second SET MEASURING REFERENCE Measuring reference can...

Страница 7: ...y after 5 minutes 3 Wheel Measurement Press mode switch button to activate wheel measurement Wheel measurement icon shows and flashes Align the reference mark for wheel measurement 5 with the starting point Roll the wheel from the starting point to the end point until the reference mark align with the end point press mode switch button again to stop the measurement the current data will be display...

Страница 8: ...G TRIPOD Use the adapter included as a standard accessory when mounting the device on a commercially available tripod Attaching the adapter Peel off the paper on the double sided tape and paste the adapter at the center of the device Adapter Screw hole Double sided tape ...

Страница 9: ...e again 220 Battery low Charge the device 255 Received signal is too weak Improve the reflective surface Use target plate or white paper 256 Received signal is too strong Improve the reflective surface Use target plate or white paper 261 Out of measuring range Measure within the appropriate range 500 Read error Switch on off the device several times and measure again WARNING To reduce the risk of ...

Страница 10: ...9 NOTE ...