LE 03 Construction
LE 03 Construction
Eject unit
Eject unit
The Eject unit has 2 trays.
The main tray is the inner tray.
The secondary tray is the Job
Separator.
Th
t
t ll d b EPS
These trays are controlled by EPS
sensor (Eject_Full_Upper) and PFS
sensor (Eject_Full_Lower), also by
JEPS (Job eject papersensor).
The capacity of the Job Separator is
normally 50 sheets 80g/m², but it is
possible to store more then 100 sheets
possible to store more then 100 sheets.
Because the system uses the upper
eject path for re-feeding the paper for
Duplex printing this might give a
problem.