2LW/2LX
1-5-33
21. Remove one connector.
22. Remove two screws-A and then
remove the HV plate.
23. Remove two screws-B and then
remove the engine R grounding plate,
engine L grounding plate and shield
plate.
24. Check or replace the engine PWB and
refit all the removed parts.
To replace the engine PWB, remove the
EEPROM from the old engine PWB and
mount it to the new engine PWB.
Figure 1-5-53
Connector
Engine PWB
Shield plate
HV plate
Screw-A
Screw-A
Screw-B
Screw-B
EEPROM
Engine L
grounding plate
Engine R
grounding plate