
2LW/2LX
1-4-22
(10)
Paper feed clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Paper feed clutch and connect-R PWB (YC5)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the paper feed clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(11)
Registration clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Registration clutch and connect-R PWB (YC6)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the registration clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(12)
Middle clutch does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Middle clutch and connect-R PWB (YC7)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the middle clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(13)
Duplex clutch does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Duplex clutch and connect-R PWB (YC9)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the duplex clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(14)
MP solenoid does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
MP solenoid and connect-R PWB (YC10)
Connect-R PWB (YC1) and engine PWB (YC9)
2. Defective solenoid.
Replace the MP solenoid.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(15)
Developing sole-
noid does not oper-
ate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Developing solenoid and connect-R PWB (YC4)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective solenoid.
Replace the developing solenoid.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
Problem
Causes
Check procedures/corrective measures
Содержание ECOSYS FS-3140MFP
Страница 1: ...SERVICE MANUAL Published in May 2013 842LX117 2LXSM067 Rev 7 FS 3040MFP FS 3140MFP ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 22: ...2LW 2LX 1 1 8 Figure 1 1 4 15 16 Original path Light path 15 Image scanner unit ISU 16 Document processor DP ...
Страница 104: ...2LW 2LX 1 3 76 This page is intentionally left blank ...
Страница 157: ...2LW 2LX 1 5 15 6 Unhook four hooks and then remove the scanner unit Figure 1 5 21 Scanner unit Hook Hook ...
Страница 210: ...2LW 2LX 2 1 15 Figure 2 1 19 Cleaning section block diagram EPWB DRPWB CL Drum Drum unit CPWB L YC504 8 ERASER Ground ...
Страница 219: ...2LW 2LX 2 1 24 This page is intentionally left blank ...
Страница 227: ...2LW 2LX 2 2 8 This page is intentionally left blank ...
Страница 251: ...2LW 2LX 2 3 24 This page is intentionally left blank ...
Страница 271: ...2LW 2LX 2 4 20 This page is intentionally left blank ...