2MH/2MJ/2MK/2ML
1-4-37
(2-1) U004XX error code table: Interrupted phase B
Error code
Description
U00420
A relay request was received from the host center but interrupted because of a mismatch
in permit ID or telephone number.
U00421
Subaddress-based relay reception was interrupted because of a mismatch in the speci-
fied subaddress relay box number.
U00430
Polling request (confidential or reverse) was received but interrupted because of a mis-
match in permit number. Or, subaddress-based bulletin board transmission request was
received but interrupted because of a mismatch in permit ID in the transmitting unit.
U00431
Confidential polling transmission was interrupted because the specified confidential box
No. was not registered. Or, an subaddress-based bulletin board transmission was inter-
rupted because the specified subaddress confidential box was not registered.
U00432
Confidential polling transmission was interrupted because of a mismatch in confidential
box ID number. Or, an subaddress-based bulletin board transmission was interrupted
because of a mismatch in Subaddress confidential box numbers.
U00433
Confidential polling request was received but data was not present in the confidential
box. Or, subaddress-based bulletin board transmission request was received but data
was not present in the subaddress confidential box.
U00434
Confidential polling request was received but interrupted because the specified confi-
dential box No. was intended for encryption.
U00435
Confidential polling request was received but interrupted because the specified confi-
dential box was being accessed. Or, subaddress-based bulletin board transmission
request was received but interrupted because the specified subaddress confidential box
was being accessed.
U00440
Confidential reception was interrupted because the specified confidential box No. was
not registered. Or, subaddress-based confidential reception or subaddress-based relay
reception was interrupted because the specified subaddress box was not registered. Or,
subaddress based confidential reception or subaddress relay command reception was
interrupted because the specified subaddress box No. was being accessed.
U00441
Confidential reception was interrupted because the specified confidential box No. was
intended for encryption.
U00450
The destination transmitter disconnected because the permit ID’s did not agree with
while the destination transmitter is in password-check transmission or restricted trans-
mission.
U00460
Encrypted reception was interrupted because the specified encryption box number was
not registered. Or, encrypted reception request was received but interrupted because
the specified encryption box was being accessed.
U00462
Encrypted reception was interrupted because the encryption key for the specified
encryption box was not registered.
Содержание ECOSYS FS-1035MFP/DP
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 25: ...2MH 2MJ 2MK 2ML 1 1 11 This page is intentionally left blank ...
Страница 97: ...2MH 2MJ 2MK 2ML 1 3 66 This page is intentionally left blank ...
Страница 141: ...2MH 2MJ 2MK 2ML 1 4 44 This page is intentionally left blank ...
Страница 157: ...2MH 2MJ 2MK 2ML 1 5 16 7 Unhook four hooks and then remove the scanner unit Figure 1 5 20 Scanner unit Hooks Hooks ...
Страница 214: ...2MH 2MJ 2MK 2ML 2 1 15 Figure 2 1 20 Cleaning section block diagram ERASER YC28 1 Drum CL CONPWB ...
Страница 218: ...2MH 2MJ 2MK 2ML 2 1 19 Figure 2 1 24 Paper exit section block diagram EXITN YC19 3 ES CONPWB Fuser unit ...
Страница 223: ...2MH 2MJ 2MK 2ML 2 1 24 This page is intentionally left blank ...
Страница 229: ...2MH 2MJ 2MK 2ML 2 2 6 This page is intentionally left blank ...
Страница 266: ...INSTALLATION GUIDE INSTALLATION GUIDE FOR PAPER FEEDER ...
Страница 267: ......
Страница 268: ......