background image

Aquam8012A/Aquam8512A Series Industrial

Ethernet Switches

Hardware Installation Manual

Publication Date: May. 2016

Version: V1.2

No.: 112023041

Содержание Aquam8012A Series

Страница 1: ...Aquam8012A Aquam8512A Series Industrial Ethernet Switches Hardware Installation Manual Publication Date May 2016 Version V1 2 No 112023041 ...

Страница 2: ... and as updated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2016 Kyland Technology Co Ltd ...

Страница 3: ...se keep the device clean if necessary wipe it with a soft cotton cloth Do not place any irrelevant materials on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed metal wires because they may be oxidized or electrified Install the device in accordance with rel...

Страница 4: ...ll damage Equipment operation or performance has abnormally changed The equipment emits odor smoke or abnormal noise The following information applies when operating this device in hazardous locations Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or nonhazardous locations only Cet appareillage est utilisable dans les emplacements de Classe I Division 2 Groupes A B C...

Страница 5: ...e T X Ethernet Port 5 4 1 1 Functions 5 4 1 2 Pin Definitions and Wiring Sequence 5 4 2 10 100 1000Base T X Ethernet Port 7 4 3 Console Port 10 4 4 Grounding 11 4 5 Power port 11 4 6 Bypass Port 12 5 LEDs 13 6 Switch Access 14 6 1 Access through Console Port 14 6 2 Access through Telnet 17 6 3 Access through Web 17 7 Basic Features and Specifications 18 ...

Страница 6: ......

Страница 7: ...er 3 switch that supports the layer 3 routing protocol The switches support panel mounting They provide up to four 10 100 1000Base T X Ethernet ports and eight 10 100Base T X Ethernet ports The 10 100Base T X Ethernet ports support IEEE802 3at compatible with IEEE802 3af POE output Each POE port can provide a maximum of 30 W feed and the entire PSE is capable of providing a maximum of 61 6 W feed ...

Страница 8: ...d ensure switch performance Table 2 Optional Accessories Model Description Remarks M12 A 4P F Female cable connector with M12 A Coding 4 Pin Power port connector M12 A 4P M Male cable connector with M12 A Coding 4 Pin Console USB port connector M12 D 4P M Male cable connector with M12 D Coding 4 Pin 10 100Base T X port connector M12 X 8Pin M Male cable connector with M12 X Coding 8 Pin 10 100 1000...

Страница 9: ...switch housing when the switch is running The figures in this manual are only for reference 11 10 100Base T X Ethernet port connection status LED 12 10 100Base T X Ethernet Port POE LED 13 10 100 1000Base T X Ethernet port 14 10 100 1000Base T X Ethernet port connection status LED Note Non PoE products do not have PoE indicators For products that support the bypass function the two gigabit ports e...

Страница 10: ...as with strong electromagnetic interference 5 Devices are to be installed in an authority certified enclosure and accessible only by the use of a tool 6 Devices should be installed and accessed by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken Mounting Step 1 Select the mounting positi...

Страница 11: ...twork device with a straight through or cross over cable 4 Connection 4 1 10 100Base T X Ethernet Port Figure 4 M12 Port female Pin Definition 4 1 1 Functions Data Transmission Serving as the Power Sourcing Equipment PSE the switches can provide power supply for PDs through 10 100Base T X Ethernet ports The 10 100Base T X Ethernet ports support IEEE802 3at compatible with IEEE802 3af POE output Ea...

Страница 12: ...d white and 8 brown The 1 and 3 2 and 4 pins on the M12 interface are differentiated signal pins in pairs The orange and white and orange pair green and white and green pair blue and white and blue pair and brown and white and brown pair in twist pair cables must be used in correct pairs while being connected with the signal pins For example the following figure the orange and white and orange and...

Страница 13: ...y You can connect the port to a terminal or network device with a straight through or cross over cable 4 2 10 100 1000Base T X Ethernet Port Figure 7 M12 Port female Pin Definition Figure 6 Connection Using Straight through Cross over Cable Facing the A direction Facing the B direction 2 3 1 4 2 3 1 4 1 8 M12 Straight through cable Cross over cable Orange and White Orange and White Orange Orange G...

Страница 14: ...J45 cable to connect the port for communi cation The preceding figures show the pin numbers of an M12 port and an RJ45 port For pin definitions see the following table Table 4 Pin Definitions of M12 RJ45 Port Figure 8 RJ45 Port 1 1 8 8 ...

Страница 15: ... 1 2 7 8 5 6 3 6 1 2 7 8 4 5 M12 RJ45 M12 M12 RJ45 1 8 1 3 4 5 6 7 8 2 1 3 4 5 6 7 8 2 Facing the A direction Facing the B direction Straight through cable Cross over cable Note The color of the cable for RJ45 connector meets the 568B standard 1 orange and white 2 orange 3 green and white 4 blue 5 blue and white 6 green 7 brown and white and 8 brown ...

Страница 16: ...nition of DB9 Port 9 Pin Serial Port and M12 Port Console Port There is a console port on the front panel The port is equipped with M12 connector Connect the console port of the switch to the 9 pin serial port of a PC with an M12 DB9 console cable You can configure maintain and manage the switch by running Hyper Terminal in Windows OS of a computer 4 3 Console Port 9 5 DB9 2 3 5 2 1 3 M12 1 1 2 3 ...

Страница 17: ...ground 4 5 Power port There is a power port on the front panel of the device You need to connect the power cable to the power port to provide power to the device Power port is equipped with M12 connector which is dustproof waterproof and anti vibration The device supports redundant power input when one power input is faulty the device can continue operating properly thereby improving network relia...

Страница 18: ...the device may be damaged To comply with UL restrictions this equipment must be powered from a source compliant with Class 2 Do not touch any exposed conducting wire terminal or component with a voltage warning sign because it may cause personal injury Do not remove any part or plug in or out any connector when the device is powered on 4 6 Bypass Port The series switches provide one or two pairs o...

Страница 19: ...el LEDs Figure 13 Bypass Port11 1 2 MAC Switch A Switch B Aquam8512A Port12 Ethernet port POE LED POE The POE port provides power supply normally The POE port provides power supply abnormally The POE port provides no power supply ...

Страница 20: ...g a Connection Step 1 Connect the console port of the switch to the 9 pin serial port of a PC with the M12 DB9 console cable Step 2 Open Hyper Terminal in Windows OS On the computer s desktop click Start All Programs Accessories Communications Hyper Terminal Step 3 Create a connection Switch as shown in the following figure ...

Страница 21: ...n port in use as shown in the following figure Figure 15 Selecting a Serial Port Note To confirm the communication port in use right click My Computer and select Property Click Hardware Device Manager Port to view the communication port ...

Страница 22: ...8 Parity None Stop bits 1 and Flow control None as shown in the following figure Step 6 Click OK to enter the switch CLI Then you can run the commands in Table 8 and Table 9 to perform operations Figure 16 Setting Port Parameters Table 8 CLI Commands for Aquam8012A ...

Страница 23: ...in Table 8 and Table 9 to perform operations Figure 17 Access through Telnet Table 9 CLI Commands for Aquam8512A Step 1 Connect the network port of the PC to the Ethernet port of the device with a network cable Step 2 On the Windows desktop click Start and Run The Run Dialog box is displayed Enter telnet IP address For example if the IP address of the switch is 192 168 0 2 default IP address of a ...

Страница 24: ...OE 101W MAX Aquam8512A without POE 18W MAX Aquam8512A wuth POE 108W MAX Aquam8012A without POE MAX 0 45A 24VDC MAX 0 22A 48VDC MAX 0 14A 72VDC MAX 0 10A 110VDC Aquam8012A with POE MAX 4 2A 24VDC MAX 1 9A 48VDC MAX 0 8A 110VDC Aquam8512A without POE MAX 0 63A 24VDC MAX 0 31A 48VDC MAX 0 20A 72VDC MAX 0 13A 110VDC Aquam8512A with POE MAX 4 5A 24VDC MAX 2 0A 48VDC MAX 0 84A 110VDC ...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...FAX 86 10 88796678 Website http www kyland com Email support kyland com For more information about KYLAND products please visit our website http www kyland com ...