SICOM3024SM Industrial Ethernet Switch User Manual
- 6 -
DC110V(82V~185V),AC220V(85V~264),DC220V(120V~370V)
Input power consumption: 35W
Over-current Protection: build-in
Mechanical parameter
Physical dimensions (height´width´depth): 88
㎜×
482.6
㎜×
245
㎜
Mounting mode: 19inch 2U stable rack mounting
Heat removal method: Single-ribbed aluminum casing for heat
dissipation without fan.
Outlet type: back outlet for service,
Shell protection: IP40
Weight: 6
㎏
Ambient conditions
Operating temperature: -40
℃~
75
℃
Storage temperature: -45
℃~
85
℃
Humidity: 5%
~
95%
(
non-condensing
)
2.2
Service Interface
1
.
1 to 24 10Base-T/100Base-TX RJ45 ports
,
Each RJ45 port has self adaptation
function, capable of automatically configuring to 10Base-T or 100Base-TX state and
automatically working in full duplex or half duplex operation mode. Support
MDI/MDI-X auto-connection. The transmission distance is 100m max.
2
.
1 to 24 pairs of redundant 100Base-FX single mode or multi-mode optical fiber
interfaces. The maximum throughput of each pair of optical fiber interface is 100Mbps,
and it is forced to work in 100M full duplex mode. They support optical fiber line
redundancy technology, with the recovery time less than 50ms.
3
.
Four redundant 100Base-LX/LC single mode or multi-mode optical fiber
interfaces or 10/100/1000Base-TX RJ45 ports. The maximum throughput of each pair
of optical fiber interface is 1000Mbps, and it is forced to work in 1000M full duplex
mode. They support optical fiber line redundancy technology, with the recovery time
less than 50ms.
4. Conform to IEEE802.3/802.3U/802.3X /802.3Z/802.ab/IEEE802.3af
5. Meanings of RJ45 port indicator: yellow lamp – rate indicator; on:100M, off:
10M; RJ45 Green lamp – connection state indicator, on: effective connection of
network; blink: network active; off: no connection. After power connection, all the
indicators light up. 30 seconds later, they work into the state described above
Содержание SICOM3024SM
Страница 1: ...SICOM3024SM Industrial Ethernet Switch User s Manual KYLAND Technology Co Ltd...
Страница 10: ......
Страница 14: ......
Страница 30: ......
Страница 34: ......
Страница 38: ......
Страница 62: ...SICOM3024SM Industrial Ethernet Switch User Manual 52 Figure 7 36 DT Ring configuration based on ports...
Страница 76: ......
Страница 83: ......