background image

3

C. Make sure the o-rings are present and positioned correctly in grooves. Moisten the o-rings with 

water. 

DO NOT USE PETROLEUM PRODUCTS TO LUBRICATE.

D. Connect KWC PURESTREAM or KWC PURESTREAM PLUS cartridge to head/bracket assembly. Align tabs 

with head/bracket assembly and push up until cartridge stops, then rotate 1/4 turn to the right to secure.

2. Cold Water Supply

Note:

Water must be diverted from the main cold water supply line to the 3/8” inlet of your KWC PURE-

STREAM filter system. Installation must comply with existing state or local plumbing codes.

Note:

Tubing runs should follow the contour of the cabinet rather than interfere with the cabinet storage

area. Arrange tubing so that there are no sharp bends. Leave some “play” in the tubing for ease of servic-
ing, then cut tubing to the desired length. Shorter tubing lengths ensure better flow rates.

A. The filter systems inlet connection is equipped with user-friendly “quick connect” push-in fittings,  

compatible with 3/8” plastic or copper tubing. Illustration 2.A shows how to use the quick connect fittings.

3. Connect System to Faucet

A. Your PURESTREAM filter system connects 

directly to the KWC faucets factory pre-
installed 8mm plastic tubing. The filter 
systems outlet connection is equipped with
a user-friendly 8mm “quick connect” 
push-in fitting.

4. Test System

A. Open cold valve under the sink.
B. The system will pressurize. Check for leaks. If 

any leaks are present, refer to troubleshooting 
section.

5. Flush Filter

A. Make sure cold water supply is turned on.
B. Flush for 3 minutes (approx. 2 gallons)  to remove any trapped air and carbon fines.
C. The system installation is now complete and ready to serve purified water. 

Enjoy!

 

Inlet

Outlet to

Faucet

Содержание PURESTREAM

Страница 1: ...INSTR2083 0202 KWC Faucets PURESTREAM Filtration System Installation and Instruction Manual KWC AMERICA 1770 Corporate Drive 580 Norcross GA 30093 Phone 888 592 3287 Fax 678 334 2128 www kwc us com ...

Страница 2: ... torch or other high temperature sources near filter or plastic cartridge Do not install near electric wires or water pipes that will be in the path of the drill when selecting the position to mount bracket Do not install in direct sunlight Allow minimum of 2 5 cm clear space under filter to facilitate cartridge change Mount filter in such a position as to prevent it from being struck by other ite...

Страница 3: ...r ease of servic ing then cut tubing to the desired length Shorter tubing lengths ensure better flow rates A The filter systems inlet connection is equipped with user friendly quick connect push in fittings compatible with 3 8 plastic or copper tubing Illustration 2 A shows how to use the quick connect fittings 3 Connect System to Faucet A Your PURESTREAM filter system connects directly to the KWC...

Страница 4: ...ill go Also check for crimps or sharp bends in tubing Water appears cloudy or air comes out of filter faucet Flush filter for a full 5 minutes to remove any carbon fines or trapped air in the filter and water lines This product is outfitted with user friendly Push In connectors Proper use of the connectors is shown in the diagrams It is most important that the tubing selected for use with these co...

Отзывы: