3
C. Make sure the o-rings are present and positioned correctly in grooves. Moisten the o-rings with
water.
DO NOT USE PETROLEUM PRODUCTS TO LUBRICATE.
D. Connect KWC PURESTREAM or KWC PURESTREAM PLUS cartridge to head/bracket assembly. Align tabs
with head/bracket assembly and push up until cartridge stops, then rotate 1/4 turn to the right to secure.
2. Cold Water Supply
Note:
Water must be diverted from the main cold water supply line to the 3/8” inlet of your KWC PURE-
STREAM filter system. Installation must comply with existing state or local plumbing codes.
Note:
Tubing runs should follow the contour of the cabinet rather than interfere with the cabinet storage
area. Arrange tubing so that there are no sharp bends. Leave some “play” in the tubing for ease of servic-
ing, then cut tubing to the desired length. Shorter tubing lengths ensure better flow rates.
A. The filter systems inlet connection is equipped with user-friendly “quick connect” push-in fittings,
compatible with 3/8” plastic or copper tubing. Illustration 2.A shows how to use the quick connect fittings.
3. Connect System to Faucet
A. Your PURESTREAM filter system connects
directly to the KWC faucets factory pre-
installed 8mm plastic tubing. The filter
systems outlet connection is equipped with
a user-friendly 8mm “quick connect”
push-in fitting.
4. Test System
A. Open cold valve under the sink.
B. The system will pressurize. Check for leaks. If
any leaks are present, refer to troubleshooting
section.
5. Flush Filter
A. Make sure cold water supply is turned on.
B. Flush for 3 minutes (approx. 2 gallons) to remove any trapped air and carbon fines.
C. The system installation is now complete and ready to serve purified water.
Enjoy!
Inlet
Outlet to
Faucet