12 : 1
Safety advice:
• Do not look into the laser beam directly.
• The beam can damage your eyes permanently.
• Do not point the laser beam at persons or reflective surfaces.
• Keep the working area clean and tidy.
• Avoid the instrument being affected by blows and impacts.
• Never expose the thermal measuring instrument to moisture and rain.
• Keep the thermal measuring instrument in a dry, secure place.
• If the thermal measuring instrument will not be used for a long time, then remove the batteries in order to avoid damage being caused by
leakage from the batteries.
• Check the thermal measuring instrument and all individual parts for damage before use. Only use the instrument if all parts are in proper condition.
• Repairs are only allowed to be carried out by skilled personnel.
• Only utilize the thermal measuring instrument for the measuring activities which are stated in the operating instructions.
• Only utilize accessories that are expressly recommended for using with the thermal measuring instrument.
• Any manipulation that leads to increasing the laser´s power is prohibited. Any liability is refused for damages which arise from non-compliance
with this safety advice.
• The thermal measuring instrument does not contain any serviceable parts. Do not open the casing for this reason because the guarantee will be
invalidated otherwise.
• Keep the thermal measuring instrument out of the reach of children.
Changing the batteries
If the instrument´s performance deteriorates, then the
batteries must be changed. Open the battery compart-
ment (7) on the instrument´s side, in order to change the
batteries. Used batteries must be disposed of properly.
Results that are measured with the thermal mea-
suring instrument must be checked generally. kwb
does not accept any liability for measuring errors and
the consequential damages resulting from them.
Technical data:
Measuring range:
-20 to +320° C (0 bis 626°F)
Operating temperature:
0° - 50°C
Power supply:
1 x 9V Block
Accuracy:
measurement 0°C to 320°C = +/- 1,5°C
or +/- 1,5%
measurement - 50°C to 0°C = +/- 3,0°C
Response time:
< 500 ms
Optics:
12:1
Laser´s wavelength:
650 nm
Maximum release of energy: 1mW
Laser class:
2
Laser radiation - Do not stare
into the beam!
Laser class 2 acc. to
EN 60825:2007
Declaration of Conformity
We, kwb Germany, declare in our sole responsibility that the
THERMO-FIXX referred to in this declaration complies with the following
standards: EN 60825:2007 EN 61000-6-1:2007 EN 61000-6-3:2007/
A1:2001 and the provisions of the Directive EMC 2004/108/EC.
kwb Produktentwicklung
kwb Germany GmbH
Hauptstrasse 132