7.3.1 -
REFILLING THE HYDRAULIC CIRCUIT WITH OIL
Figure 7.3 – A
The hydraulic circuit needs to be refilled with oil after a continuous
use, and when you notice a reduction in the tool stroke.
Proceed as follows (see Picture 7.3-A):
Disconnect the airline from the tool inlet.
Unscrew the manostat (
A
) with relevant wrench
54
;
Remove cap together with relevant washer
27
.
Put the tool in horizontal position and slowly pour in the hydraulic oil (ISO VG 32 type)
50
until the circuit is full.
Screw cap back on, together with relevant washer
27.
Connect the tool to compressed air line and start up a couple of idle cycles. Stop pulling the trigger and slowly
loosen screw
27
; make sure that the circuit is full with oil and that no air bubbles are left inside.
Wear gloves when managing the oil.
Do not
throw the old oil outdoors but hand it over to an authorised waste disposal centre.
Warning!: if you should accidentally spill oil on your skin, wash and rinse thoroughly with water and alkaline
soap
.
7.3.2 -
PARTS SUBJECT TO WEAR
On a periodic basis check the state of wear of the rubber base, as this is what ensures the stability of the tool. If it should
need replacing, order the spare base from KVT - FASTENING indicating the year/serial number of the tool (see section
4.5).
On a periodic basis check the state of wear of the screws and of the heads and, if necessary, replace them as indicated in
section 6.2.
Spare parts are to be ordered exclusively from KVT - FASTENING, specifying the codes listed in section 3.1.