background image

 

 

TYPE 9106                                                 07/2014 

 

 

Dear Customer, 

Thank you for purchasing of the appliance KVS MORAVIA. We trust that our product serves you 
well.  Some  important  principles  should  be  observed  during  its  operation.  Therefore,  in  your 
interest,  carefully  study  this manual and  operate  the  product  according  to  the  given  instructions. 
The 9106 appliance has a manufacturer issued declaration of conformity according to Section 12, 
Article 3, of Law No. 22/1997 of the Czech Republic.   

 

 

 

When  starting  a  fire,  do  not  use  any  flammable  liquids,  do  not  use  any  such  substances  to 

extend the nominal heat rating of the appliance. 

 

The  appliance  must  not  be  used  for  the  incineration  of  waste  material,  only  recommended 

fuel types may be used. 

 

When  the  appliance  is  in  operation,  the  ash  receiver  gate  must  be  closed.  To  prevent  the   

leakage  of  fumes,  the  combustion  chamber  gate  may  only  be  open  when  adding  fuel  or    

operating the grate. 

 

The appliance may only be operated by adults. 

 

Ash may only be put in a container made of fire-resistant material. Exercise maximum caution 

when handling hot ash. 

 

Observe fire safety. 

 

A damaged appliance (i.e., an appliance unfit for operation) must not be used. 

 

If  these  operating  conditions  are  not  adhered  to,  the  appliance  may  become  damaged.  It  is 

strictly forbidden to overload the appliance in any way. 

 

There  may  be  sudden  sharp  knocks  (throbbing)  of  the  metal  plates  inside  the            

appliance.  These  events  to  not  qualify  for  guarantee  repair  or  a  customer  claim         

procedure. The above noises are caused by the inner tension in the metal plates, these 

noises will die away over time, depending on the frequency of the heating occasions. 

These defects do not put the appliance´s safety or functionality at risk.

 

 

Any and all repairs of the appliance must be performed by certified repair staff. 

 

Any and all local regulations, including those regulations that refer to national and European 

standards, need to be adhered to during the installation of the appliance. 

 

Use only spare parts which have been approved by the manufacturer. 

 

Any unauthorised modifications of the appliance are forbidden. 

 

The appliance should be installed by an outhorised specialist. No claims are accepted 

in case of incorrect or amateur installation. 

 
 
 

OPERATION & MAINTENANCE MANUAL 

Important Information, Binding Instructions and Recommendations 

Содержание 9106

Страница 1: ...TYPE 9106 07 2014 TYPE 9106 OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL SOLID FUEL RANGE COOKER WITH HOT WATER HEATING ...

Страница 2: ...TYPE 9106 07 2014 1 ...

Страница 3: ...ng hot ash Observe fire safety A damaged appliance i e an appliance unfit for operation must not be used If these operating conditions are not adhered to the appliance may become damaged It is strictly forbidden to overload the appliance in any way There may be sudden sharp knocks throbbing of the metal plates inside the appliance These events to not qualify for guarantee repair or a customer clai...

Страница 4: ...ting section 7 kW Heat flow into the surrounding environment 0 23 kW Efficiency at NHO 72 7 Average fume temperature NHO 200 C Mass of fume flow NHO 10 g s Average CO content at NHO při O2 13 0 4 Minimum chimney effect 12 Pa Work surface height distance from floor to hob top panel 850 mm Appliance width 325 mm Appliance depth 640 mm Fume outlet diameter 130 mm Height to the centre of the fume outl...

Страница 5: ...ack side only The hotplate lid is packaged separately for ease of transportation After the appliance has been unpacked insert the hinge pins into the openings at the rear section of the hotplate frame The springs in the hinges assist in keeping the lid in a vertical position The hotplate lid is supplied upon the customer s request NOTE The manufacturer reserves the right to carry out small changes...

Страница 6: ... Regulation The volume of incoming air is adjusted with the regulator that is not included in the appliance The regulator unit facilitates the operation of the appliance maintains the selected heating output and prevents the appliance from overheating The operation of the regulator is based on the water temperature inside the system As the temperature of the heating water rises the device limits t...

Страница 7: ...TYPE 9106 07 2014 6 Figure 2 ...

Страница 8: ... port The entire combustion chamber may be used for incineration Make sure the fuel does not fall outside the chamber during addition In adverse chimney effect conditions or in bad weather conditions use small dry logs of wood Long term Operation The appliance may be in unattended operation for an extended period of time as follows after the base layer of hot material fill the fuel chamber and tur...

Страница 9: ...irt use detergent cleaning products Do not expose the hotplate to water if possible as corrosion might develop Clean the plate dry If a wet cloth with detergent is used for cleaning remember to dry the hotplate afterwards It is recommended to apply a thin layer of vegetable oil occasionally Fire may not be started check the cleanliness of the fume duct smoke pipe and chimney check the settings of ...

Страница 10: ...lid fuel appliances are produced in accordance ČSN EN12815 2002 Standard with amended A1 2005 which is valid for the Czech Republic and European Union 2 Installation and operation standards All the above installation and operation instructions for the appliances primarily comply with the Czech regulations and may not comply fully to individual national regulations at place of installation and use ...

Страница 11: ... and diameter of 160 mm Try to have the connection between the appliance and the chimney as short as possible Any smoke ducts made of tin pipes consists of several sections and longer than 2 000 mm must be firmly fastened The entire system must be connected correctly and tightly in the direction of the smoke travel Individual pipes must overlap at a minimum of 80 mm The chimney connection shall be...

Страница 12: ...rotected material at a distance of 30 5 mm from the protected material The protective screen shall exceed the protected material to the nearest wall ceiling of flameproof material at a minimum of 300 mm on the upper side and 150 mm on the sides We recommend that your installer check this reduced dimension with your local building control department Description of materials type for flammable class...

Страница 13: ...TYPE 9106 07 2014 12 Flue gas ducting connection to the Chimney valid for Czech Republic properly improperly Figure 3 ...

Страница 14: ...ater temperature during consolidated operation does not drop below 65 C Note The drain fill cock is a part of the appliance the pressure gauge is not included in the appliance The installation of the cock must be located in the lowest section of the system and the pressure gauge this should be located as close to the appliance as possible comply with the individual national regulations at place of...

Страница 15: ...TYPE 9106 07 2014 Figure 4 ...

Страница 16: ...6 07 2014 Producer KVS EKODIVIZE a s Plant Dvorce Opavská 272 793 68 Dvorce u Bruntálu CZECH REPUBLIC Telephone 420 554 797 111 Telefax 420 554 745 500 E mail prodej dvorce kvs ekodivize cz www kvs ekodivize cz ...