Requirements
31
www.kvm-tec.com
10
Requirements
Requirements for Cat 5/6/7 cables:
The pins are connected 1:1
Caution: the cable pairs must be twisted to EIA/TIA-568A (rare) or EIA/TIA-568 B
(common) pairs!
Erroneous assignments can not be found with a simple cable tester.
The pins for the green pair of wires are not adjacent to one other! The cable
must at the very least meet the Cat5 specifications and be suitable for Gigabit
transmission.
Applicable standards: Class D ISO/IEC 11801:2002 or EN 50173-1:2002.
Schema EIA/TIA-568 B
Requirements fibre
Multi-Mode (standard)
Included with the MVX1-F is a LWL Multimode – SFP
Module which allows a transmission distance of up to
500m.
Requires dedicated fibre connection, cable type Duplex
Multimode 50/125
μ
(OM2), LC connector
Single-Mode (optional)
LWL Singlemode – SFP Module up to 20km transmission distance
Requires dedicated fibre connection, cable type Duplex Singlemode, LC
connector
LWL Singlemode – SFP Modul BiDi up to 20km transmission distance
Requires dedicated fibre connection, cable type Singlemode, LC connector
Wavelength ( ) 850nm in multimode
1310nm TX – 1550nm RX in singlemode
Pin
Color
1
Orange
/White
2
Orange
3
Green
/White
4
Blue
5
Blue
/White
6
Green
7
Brown
/White
8
Brown
Shielded installation cable with min.
cross section of 24AWG throughout the
length, shield is continguous and
connected to both ends.
Shielded patch cable is allowed for
connection to the device.