SWITCHING Menu Guide / Settings
25
www.kvm-tec.com
Access to the network settings is always protected by a login and password, even
when the password system is disabled.
6.2.3
Network Settings Mode Item “C” – Auto Connect
If your connection is interrupted by another user the switching system will
automatically connect you with a free computer when the Auto Connect setting
is active.
This function is unavailable while using the Password System.
6.2.4
Network Settings Mode Item “V” – Private Connections
By activating the private connection function, users can set up a private
connection with a computer, which can’t be interrupted by other users.
To establish a private connection hold down “<Shift>” while you select a new
connection (either in the switching menu or by pressing the hotkey combination).
See
item
7 Switching
.
6.2.5
Network Settings Mode Item “B” – User-PC Binding
When in the User-PC Binding mode the switching system behaves quite
differently. Each console start unconnected and displaying the log in screen (Fig.
11). The switching menu and switching hot keys are not available. The admin
must configure each user to have a specific PC bound to them (
see 6.1.2
). When
a user logs on they will be automatically connected to their bound PC. If another
user wishes to use the console the first user must disconnect and logout with
the key combination Ctrl-Alt-F11.
Users with Master or Admin rights are able to access the switching menu as
normal once they’ve entered their login details.