Analog Signal Strength Report
Function:
reports signal strength from RF detector circuit in
A/D counts (000-FFF Hex)
Command:
SIGLEVEL
Argument:
none
Response:
Signal Strength = xxxx
E.5
RF Board Commands
Serial Communications, Status/Polarization Report, Tone Changes
Function:
start serial communications, reports status &
polarization/tone changes
Command:
@S
Response:
S,s,p,b,m <cr> every 5 seconds until ><cr>is
returned from system software
Where:
s = Satellite (a = Primary, b = Secondary)
p = Polarization (v = Vertical, h = Horizontal,
r = Right, l = Left, x = No LNB Power)
b = Band (h = High Band, l = Low band, u = USA)
m = Mode (v = Valid, i = Invalid)*
* The Mode bit is used to evaluate the Satellite, Polarization, & Band
combination vs. the Frequency/Symbol Rate/FEC currently in RAM. This bit will
be set to invalid if the Frequency for the selected combination is set to 0x0000;
otherwise it will be set to valid.
E-5
Maintenance Port Parser Commands
54-0159 Rev. G
Table E-5
RF Board Commands