2. Open the terminal emulation software and
establish the following settings:
• 9600 baud
• no parity
• 8 data bits
• 1 start bit
• 1 stop bit
• no flow control
3. Apply power to the TracVision C3 system and the
IRD and allow the system to complete full
initialization. Data should be scrolling on the PC
display to identify any system problems detected.
If no data is seen, recheck your connections and
the terminal software setup. A sample startup
sequence has been provided in
4. After completing the review of the startup and
operational routines, turn on the IRD and
television and check the channels on the selected
satellites. For European systems, view both
horizontally and vertically polarized channels, if
possible.
5. When all checks are completed, shut down the
system.
2-25
Installation
54-0159 Rev. G
If a need arises to paint the
radome, only use non-metallic
paint to avoid degrading the RF
signal strength and the reception
quality. The KVH warranty does not
cover degraded performance
resulting from a painted radome.