Follow these steps to prepare and route the RF,
power, and data cables to the antenna location.
You need to connect two
75
RF coax cables
from the antenna location to the ICM. Refer to
Figure 12 to determine the type of cables and
connectors you can use for your cable run. Then
prepare the cables as described below.
* Cables from KVH include the proper connectors.
** LMR tool kits from KVH include a torque wrench.
RG-11
Max. length
100 ft (30 m)
KVH part no.
50 ft (15 m): S32-0566-50
100 ft (30 m): S32-0566-0100
Connector
Belden SNS11AS*
Tools
Belden CST596711, L3011B
(KVH part no. 72-0493)
Strip lengths
LMR-400-75
Max. length
200 ft (60 m)
KVH part no.
100 ft (30 m): S32-0944-0100
150 ft (45 m): S32-0944-0150
200 ft (60 m): S32-0944-0200
Connector
Times Microwave EZ-400-FMH-75*
Tools
Times Microwave TK-400EZ-75
(KVH part no. 72-0374-75**)
Strip lengths
LMR-600-75
Max. length
325 ft (100 m)
KVH part no.
150 ft (45 m): S32-0945-0150
200 ft (60 m): S32-0945-0200
300 ft (90 m): S32-0945-0300
Connector
Times Microwave EZ-600-FMH-75*
Tools
Times Microwave TK-600EZ
(KVH part no. 72-0375-75**)
Strip lengths
If you use RG-11 RF cables 80-100 ft (25-
30 m) in length, you can avoid the modem
commissioning step. See Commission
the Modem on page 32.
RF cables must be rated for
75
, not 50 .
Low-quality, poorly terminated, or
improperly installed RF cables are the
most common cause of system problems.
Terminate all RF cables with high-quality
F connectors using the proper
stripping/crimping tools, exactly to the
manufacturers specifications.
See page 48
for instructions on terminating LMR cables.
Do not use RG-6 cable, as it will damage
the system. Use of any cables not specified
in Figure 12 will void the warranty.
Make sure the center conductor pin at
each end of the finished cables is free of
burrs and 1/4" (0.20"-0.28") (5-7 mm) in
length, measured from inside the nut to
the tip, to ensure proper engagement.
(LMR cables only)
Make sure there is no
gap between the end of the cable jacket
and the start of the connector.
When determining cable lengths, dont
forget to account for service loops, 14"
(35 cm) in diameter, at each end.
IMPORTANT!