i
28
EN
2.8
switching on sequence and user interlock
!
Please make sure that all laser display
safety requirements are fulfilled
in accordance with laws of the country
where this KVANT laser system is being
used before switching the system ON.
1. Connect the system as showed on Connection
Diagram.
2. Turn E-STOP Remote and safety key to ON position.
3. Turn Shutter key to ON position
4. Release the E-STOP button by pulling it upwards.
5. Press the START button on the E-STOP Remote.
6. After an Emission Delay Period the Architect laser
system will be ready for use.
Interlock Enabled, Laser Output Terminated
The laser emission of running Architect laser system will
be terminated if any of the following events happen:
1. Power loss lasting greater than 2 seconds.
2. Mushroom emergency switch depressed.
3. Safety key Switch on E-STOP Remote turned to OFF
position.
4. Shutter key turned to OFF position
5. E-STOP Remote disconnected from KVANT Architect
laser system.
6. Door interlock circuitry connected to the E-STOP
Remote interlock connector is open. Door interlock
may be replaced by the user’s own interlock system
using a switch or dry relay closure to connect pins
1 and 2 of the E-STOP Remote interlock connector.
With pins 1 and 2 shorted, Laser Emission is possible,
while all other interlock conditions are in active state.
With pins 1 and 2 open, NO Laser Emission is possible.
Refer to Connection Drawing below.
7. Cover interlock is opened by removing the top cover.
Restarting Laser After Interlock or Power Failure
Event
After the event has been corrected the START button
on the E-STOP Remote must be pressed by the operator
to disable the Interlock and after an Emission Delay period
the laser projector will be ready for use.
Interlock Connection Diagram