12
i
28
EN
2.7
multiple system interlock
Multiple Kvant Architect laser systems may be operated and
controlled by a single E-STOP Remote. In order to do this,
the remote cables from all Architect laser systems must
be plugged into E-STOP outputs of the E-STOP splitter
(either 8 or 12 channel output version). Remote cable
of each Architect laser system should be plugged into
individual output of E-STOP splitter. This device ensures
proper functionality and distribution of E-STOP commands
from the E-STOP Remote to each plugged Architect laser
system and they are fully compatible with all Kvant laser
systems using E-STOP Remote standard. The E-STOP
splitter has two inputs, thus two E-STOP Remotes can
be used and you can control the Architect laser systems
from two different locations. The START buttons of all
plugged E-STOP Remotes must be pressed by the operator
to disable the interlock and enable the emission. After
an Emission Delay period the laser projectors will be ready
for use. The E-STOP splitter is not included with the supply
and needs to be ordered separately.