Lubrication Requirements
3-5
KVAL EP-1 Operation/Service Manual
Gear Motor Lubrication Requirements
Oil change is recommended after 2000 operation hours of operation. Use AGMA #8 gear lube or
MOBILUBE HD 80 W-90 or equivalent.
Description of Air Input System
The air input system takes in shop air and supplies clean dry air (CDA) and lubricated air to the
machine. The clean dry air is diverted to blow off nozzles. The lubricator, located after the CDA
filters, delivers the lubricated air to valve banks and air cylinders.
Shop
Air
Input
Air On-
Off Knob
Muffler
Filter
(w/purge )
Pressure Gauge with adjust
Clean Dry Air (CDA) to
Air Blow Off
Lubricator
Lubricated
Air Output
FIGURE 3-2.
Typical Air Line Filter and Lubrication System
Adjusting the Air Line Lubricator
Using the knob on the top of the lubricator, adjust until one drop per every other cycle is used (as
observed through sight glass.)
(Sight glass). Drop will form at
end of cane shaped tube visi-
ble inside glass.
(Adjustment knob). When the oiler has run
dry, open the knob all the way until flow
begins. Once you have a steady flow,
tighten knob back down until you have one
drop per every other cycle.
Top
Содержание EP-1
Страница 1: ...Innovation Quality Honesty Operation and Service Manual Published 1 23 15 EP 1 Edge Prep Machine ...
Страница 4: ...KVAL EP 1 Operation Service Manual ...
Страница 20: ...Getting Help from KVAL 1 14 KVAL EP 1 Operation Service Manual Page Intentionally Left Blank ...
Страница 22: ...Safety Sign Off Sheet 1 16 KVAL EP 1 Operation Service Manual ...
Страница 38: ...How to Power Down the EP 1 2 16 KVAL EP 1 Operation Service Manual ...
Страница 56: ...Troubleshooting the Air Cylinders 4 12 KVAL EP 1 Operation Service Manual ...