Sample of Grease Locations for the Machine
KVAL Commander III Service Manual
3-22
Servo Grease Locations
Use an extender to reach tight areas. Make sure to
Lockout/Tagout
before maintenance. For rec-
omme
Extension Adapter
Needle Nozzle
It is recommended to use an extension needle in applying grease to the
Outfeed Stop Servo Assembly
grease points
nded lubrication schedule,
see “Lubrication Schedule” on page 3-15.
The Lock Location Servo Assembly is attached to the back section.
The Outfeed Stop Servo Assembly is located at the end of the machine on the inside front sec-
tion.The Assembly is accessed by way of a cut out section on the frame.
FIGURE 3-11.
Servo Motor Assembly Bearings
Tapered Bearing Housing
Recommend One a Pump4 X a
Year Maximum
Pillow Block (Hub
Style
Recommended
every 250 Hrs
Ball Screw Nut
Recommended
every 80 Hrs
Servo Motor
Servo Motor
Pillow Block (Hub
Style
Recommended
every 250 Hrs
Ball Screw Nut
Recommended
every 80 Hrs
Outfeed Stop Servo Assembly
Lock Location Servo Assembly
Содержание Commander III
Страница 5: ...KVAL Commander III Service Manual KVAL Commander III Service Manual ...
Страница 10: ...Notes ...
Страница 29: ...How to Download the Service Application 1 19 KVAL Commander III Service Manual Page Intentionally Left Blank ...
Страница 31: ...Safety Sign Off Sheet 1 21 KVAL Commander III Service Manual ...
Страница 36: ...Notes ...
Страница 75: ...Collet Torque Values 3 39 KVAL Commander III Service Manual ...
Страница 76: ...Collet Torque Values KVAL Commander III Service Manual 3 40 ...
Страница 100: ...Network System Overview KVAL Commander III Service Manual 4 24 ...
Страница 103: ......