Electrical circuitry on this
machine is protected by an
approved lockable disconnect
circuit. In addition to this equip-
ment, you must install an
approved disconnect for the
electrical power supplying this
machine.
When opening the cabinet you must first turn off the
disconnect switch. When the cabinet door is open there
is
still power on the top side of the disconnect switch
.
Some machines are powered by more than one supply
located at different locations. Before performing any repairs or mainte-
nance, lockout and tagout
must be installed at all locations
All maintenance and repairs to electrical circuitry should only be per-
formed by a qualified electrician.
Still has power
in OFF position
Electrical
Prior to performing any maintenance, repairs,
cleaning or when clearing jammed debris, you
must disconnect, tag out, or lock out the electrical
and air pressure systems. This should be done in
accordance with applicable state and/or federal
code requirements.
Before Conducting Maintenance
Laser Warnings
On some machines, laser indicators are used to set boundaries. Follow the
manufacturers safety precautions.
Safety First!
1-7
990-HQ Service Manual
Содержание 990-HQ
Страница 4: ...KVAL 990 HQ Service Manual ...
Страница 9: ...Notes ...
Страница 27: ...How to Download the Service Application 1 18 990 HQ Service Manual Page Intentionally Left Blank ...
Страница 29: ...Safety Sign Off Sheet 1 20 990 HQ Service Manual ...
Страница 38: ...Network System Overview 2 9 990 HQ Service Manual ...
Страница 65: ...Lubrication Points on the 990 HQ 3 27 990 HQ Service Manual FIGURE 3 18 Bearings Back Section ...
Страница 79: ...Collet Torque Values 3 41 990 HQ Service Manual ...
Страница 80: ...Appendix Conversion Chart 3 42 990 HQ Service Manual Appendix Conversion Chart ...
Страница 81: ...Appendix Conversion Chart 3 43 990 HQ Service Manual ...
Страница 108: ...Troubleshooting with the Status Light Panel 4 27 990 HQ Service Manual ...
Страница 111: ......