Troubleshooting the Air Cylinders
4-23
KVAL 990-F4 Service Manual
Troubleshooting the Air Cylinders
Most cylinders have an extend and retract port. To adjust the extend motion of a cylinder you
must adjust the flow control on the retract port; this regulates the air flow exhausting from the cyl
-
inder and the opposite is true for the retract motion.
1.
Check the air pressure to the machine.
2.
Check the flow controls to see that they are adjusted correctly and to the proper
specifications.
3.
Check for any obstructions to the cylinders such as
screws or a misplaced tool etc. FOLLOW ALL
SAFETY GUIDELINES AND SIGNS DURING
THIS PROCESS.
4.
Check the solenoid air valves:
Manual over-
ride button