background image

VHD3200D · Getting started 

Unpacking

Unpack the VHD3200D and check to see if there is any damage to it. If you find any damage notify your supplier immediately. 
Only the consignee may institute a claim with the carrier for damage incurred during shipping. Be sure to save the carton and 
all packing materials for the carrier's inspection.

Should you ever need to ship the unit, only use the original factory packaging. If the shipping carton is unavailable, contact 
your supplier to obtain a replacement.

The VHD3200D carton should contain: 
•  VHD3200D amplifier control unit               •     User's Guide               •     PowerCon detachable power cable

Rack Mounting

VHD3200D's will mount in standard 19" rack systems. Integral rear mounting rack ears are also provided for additional 
support, do not rely on fixing and mounting the VHD3200D using just the front panel as support. Use eight screws  
and washers to mount the amplifier to the equipment rack rails (four for the front and four for the rear). We recommend 
using a shock mounted rack for touring use to prolong the life of your VHD3200D.

AC Requirements

Two PowerCon cables are provided to connect the VHD3200D to a suitable AC power supply.

The PowerCon is a connector without breaking capacity, i.e. the PowerCon should not be connected or disconnected 
under load or while it is live. Always isolate your AC supply before disconnecting the PowerCon connector.

Your VHD3200D will be supplied pre set to the voltage used in your area. The table below provides typical current draw 
figures for the VHD3200D.

Cooling

The VHD3200D has a comprehensive cooling system featuring chassis-sealed PCB board mounting and shock mounted, 
speed controlled fans. This means that the cooling system never drives air across PCB boards, connectors or components 
ensuring prolonged electronic component lifespan and minimizing maintenance cycles.

Air is drawn into the front of the amplifier by the two fans on the rear panel, this passes over the cooling fins of the heat sinks 
and exhausts through the rear. If the heat sink gets too hot, its sensing circuit will open the output relay, disconnecting the load.

It is important to have an adequate air supply at the front of the amplifier, and enough space around the rear of the amplifier to 
allow the cooling air to escape. If the unit is rack mounted, do not use doors or covers on the rear of the rack; the exhaust air must 
flow without restriction. If you are using racks with closed backs, use fans on the rear rack panel to ensure an ample air supply.

IMPORTANT! Please note that for correct full performance of the unit AND ANY WARRANTY COVER,  
it is important that regular maintenance of the front vents and filters as well as the rear panel fans be inspected  
and cleaned by removing any dust and debris build-up. Any product failure due to lack of attention in this matter will 
immediately void any current warranty. (Please refer to notes re ventilation procedures).

AC Input

Current draw with amplifier running

at Average Power (Each Channel)

Current draw with amplifier running

at Peak Power (Each Channel)

250V

5.5A

11A

230V

6A

12A

115V

12A

24A

Remember that if you are connecting both AC cables for the VHD3200D to the same AC power source then you will 
need to have double the per channel current available.

4

VHD3200D  ·  G

etting star

ted

Содержание KVV 987 446

Страница 1: ...develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectations User Guide VHD3200D ...

Страница 2: ......

Страница 3: ... any way such as when the power supply cord or plug has been damaged liquid has been spilled or objects have fallen into the Vents rain or moisture has entered the Amplifier the Amplifier has been dropped or when for undetermined reasons the Amplifier does not operate normally 15 Do not remove front or back panels Removal of the panel will expose hazardous voltages There are no user serviceable pa...

Страница 4: ...duction Dimensions 3 Getting Started 4 Unpacking Rack mounting Cooling AC Requirements 4 Front Panel 5 Rear Panel 6 7 Display menu description 8 Remote management 9 12 Overview 9 Channels 10 Diagnostics 11 Settings 12 Specifications 13 Warranty Service 14 Notes 15 16 ...

Страница 5: ...ery highpowered device that can put out high voltages and sizable currents Always use safe operating techniques with the VHD3200D FOR YOUR SAFETY READ THE IMPORTANT PRECAUTIONS SECTION AS WELL AS THE INPUT OUTPUT AND POWER CONNECTION SECTIONS OF THIS MANUAL VHD3200D part number KVV 987 448 250V KVV 987 447 230V KVV 987 446 115V Application Specifically designed to drive all VHD ES SL subwoofer ele...

Страница 6: ...D has a comprehensive cooling system featuring chassis sealed PCB board mounting and shock mounted speed controlled fans This means that the cooling system never drives air across PCB boards connectors or components ensuring prolonged electronic component lifespan and minimizing maintenance cycles Air is drawn into the front of the amplifier by the two fans on the rear panel this passes over the c...

Страница 7: ...speaker protection limiter has been activated for that particular channel of the amplifier 3 Power ON Thermal Autoreset These are dual colour LED s When green they indicate that the Power Switch is ON and that channel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 4 Mu...

Страница 8: ...one channel One for each channel of the VHD3200D both must be connected to operate both channels of the VHD3200D They accept standard PowerCon terminated AC Mains cables 4 Fans The cooling fans operate continuously while the VHD3200D is on An internal temperature sensor increases the speed of the fans during high temperature conditions Air enters through the front grille and exits through the rear...

Страница 9: ...rnal communication port supporting Ethernet standard accepts RJ45 T 658B wiring The VHD3200D provides web server and SNMP Simple network management protocol When the Ethernet cable is connected and devices successfully establish a connection the green LED is activated When Ethernet communication is in progress the orange LED flashes 8 Speaker AP4 Connectors One for each channel of the VHD3200D Acc...

Страница 10: ...is pattern 169 254 x y where x and y are any two numbers between 0 and 255 Unlike DHCP Auto IP does not require a router or a separate server to assign an IP address Selected IP address is displayed on display section NET or can be obtained using KV2 diagtool software DHCP Dynamic Host Configuration Protocol A DHCP server enables network devices to request IP addresses and networking parameters au...

Страница 11: ... Shows the information assigned by user of the amplifier Description Amplifier name Location Contact Uptime and Firmware revision Network status Shows the amplifier ethernet network address netmask mode and status Power Shows the amplifier power sources status Mains power A B Channel A B power sources Power over Ethernet PoE Temperature Shows the amplifier channel A B heat sinks temperatures and D...

Страница 12: ...plifier diagnostics information Mains voltage Signal Green when input signal is present Speaker protection Orange when speaker protection hits Temperature Output voltage Shows the amplifier speaker output voltages Output current Shows the amplifier speaker output currents Calculated impedance Shows the amplifier speaker output connected speaker impedances 10 VHD3200D Remote management ...

Страница 13: ...cs together Channel A B Sums amplifier channel diagnostics information Power source Temperature Health amplifiers A B working OK with dedicated gain Temperature Displays amplifiers heat sinks A B temperatures C Protection When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 11 VHD3200D Remote management ...

Страница 14: ... identification Shows and sets the device local information Device name Location Contact Security Sets name and password for web server security default User name admin default Password admin Network Sets the Ethernet IP mode AutoIP DHCP default Static IP address and netmask must be set 12 VHD3200D Remote management ...

Страница 15: ...tput Main Through OUT Speaker Output Speaker Output 2x AP4 1x AP4 bridge Features System setup Limiter Short protection Network Ethernet SMNP Webserver Power Power Connector 2x Neutrik PowerCon Operating Voltage 115V 230V 250V Operating Voltage Range 100 to 120V 60Hz 205 to 240V 50Hz 225 to 260V 50Hz Recommended Amperage 2 x 20A 115V 2 x 10A 230V 2 x 10A 250V Soft Start YES Protection Thermal brea...

Страница 16: ...d distributor service centre or shipped directly to our factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your nearest KV2 Audio Service Ce...

Страница 17: ...VHD3200D Notes 15 VHD3200D Notes ...

Страница 18: ...VHD3200D Notes 16 VHD3200D Notes ...

Страница 19: ......

Страница 20: ...KVV120148 00 01 0 KV2 Audio International Nádražní 936 399 01 Milevsko Czech Republic Tel 420 383 809 320 Email info kv2audio com www kv2audio com The Future of Sound Made Perfectly Clear ...

Отзывы: