background image

+B

ASS

CHANNEL 2

CHANNEL 1

 SIGNAL 

/

LIMITER

LIMITER

ON

 PO

WER /

 THERMAL

+B

ASS

 SIGNAL 

/

LIMITER

LIMITER

ON

 PO

WER /

 THERMAL

-6 dB

8

-6 dB

0 dB

8

0 dB

W

A

RNIN

G

:

 T

O

 REDUCE 

THE RISK OF ELECTRIC SHOCK DO NO

T REMO

VE 

THIS P

ANEL OR 

ANY 

A

TT

A

CHED COMPONENTS

. NO OPERA

TOR SER

VICEABLE 

PA

RTS INSIDE.

 REFER SER

VICING 

TO

 QU

ALIFIED PERSONNEL ONL

Y.

 T

O

 

REDUCE 

THE RISK OF FIRE OR ELECTRIC SHOCK,

 DO NO

T EXPOSE 

THIS 

APPLIANCE 

TO

 RAIN OR MOISTURE.

 

SERIAL NUMBER

WWW.KV2AUDIO.COM

 KV2 AUDIO,  MANUFACTURED IN THE EUROPEAN UNION

2000W / 4

Ω

BRIDGE

min. 

2

Ω

  

OUTPUTS 

OFF

ON

The future of sound.
Made perfectly clear.

At KV2 Audio our vision is to constantly develop 
technologies that eliminate distortion and 
loss of information providing a true dynamic 
representation of the source.

Our aim is to create audio products that absorb 
you, place you within the performance and deliver 
a listening experience beyond expectation. 

ESP2000

User Guide

Содержание ESP2000

Страница 1: ...R ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE SERIAL NUMBER WWW KV2AUDIO COM KV2 AUDIO MANUFACTURED IN THE EUROPEAN UNION 2000W 4Ω BRIDGE min 2Ω OUTPUTS OFF ON The future of sound Madeperfectly clear At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to ...

Страница 2: ...ed against defects in material and workmanship Refer to your supplier for more details Service In the unlikely event that your ESP2000 develops a prob lem it must be returned to an authorised distributor service centre or shipped directly to our factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If th...

Страница 3: ...tput Do not connect the ESP2000 output to any other voltage source such as a battery mains source or power supply regardless of whether the ESP2000 is turned on or off 17 Do not run the output of any ESP2000 back into another channels input 18 Refer all servicing to qualified service per sonnel Servicing is required when the amplifier has been damaged in any way such as when the power supply cord ...

Страница 4: ...o channels within a two rack unit chassis It can be used to power any range of passive loudspeakers as well as being specifically designed for opti mised performance with KV2 Audio s ESD Series Whilst this unit is simple to operate improper use can be dangerous This is a very high powered device that can output high voltages and sizeable currents Always use safe operat ing techniques with the ESP2...

Страница 5: ...with closed backs use fans on the rear rack panel to ensure an ample air supply AC Power Requirements The ESP2000 is an advanced power amplifier Understanding power distribution voltage and current requirements as well as electrical safety issues is critical to the safe operation of the ESP2000 AC Power The ESP2000 uses a single PowerCon 3 pole AC main systems with locking connectors to prevent ac...

Страница 6: ...eate inter national or special purpose power connectors Current Requirements Each of the ESP2000 s power supply inputs require approximately 20 Amps max at 115V AC for proper operation This means that both of the ESP2000 s power supplies must be powered from an individual 20 A breaker when running in 115V mode When operating in 230 V mode each of the ESP 2000 s power supply inputs requires approxi...

Страница 7: ... audio cable Reconnect the power cord only after making all signal connections Connect the amplifier to a two pole three wire grounding mains receptacle The receptacle must be connected to a fuse or circuit breaker Connection to any other type of receptacle poses a shock hazard and may violate local electrical codes Do not allow water or any foreign object to get inside the amplifier Do not put ob...

Страница 8: ...ey indicate that the Power Switch is ON and that chan nel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 6 Signal Present Limiter Indicator These are dual colour LED s When green they indicate that signal is present at the Input to that particular channel of the amplif...

Страница 9: ...FER SERVICING TO QUALIFIED PERSONNEL ONLY TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE SERIAL NUMBER WWW KV2AUDIO COM KV2 AUDIO MANUFACTURED IN THE EUROPEAN UNION 2000W 4Ω BRIDGE min 2Ω OUTPUTS OFF ON 1 2 4 3 4 5 NOTE If Bridge Mono is your specific requirement particularly driving subwoofers you may prefer to utilise a KV2 Audio VHD3200 subwoofer a...

Страница 10: ... RMS Out Power 2Ω 1 channel 2 channels loaded 1000W 800W RMS Out Power 16Ω bridged 600W RMS Out Power 8Ω bridged 1000W RMS Out Power 4Ω bridged 1500W RMS Signal Input Input Channels XLR Input Sensitivity 1 55V Input Impedance 20kΩ balanced Signal Output XLR Through Speaker Output Speaker Output Neutrik Speakon 2x Binding posts Features Level Control 0dB Subwoofer Level Control 6dB 60Hz RMS Limiter...

Страница 11: ......

Страница 12: ...o com KVV120080 00 04 0 At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectation ...

Отзывы: