KV2 Audio ESP2000 Скачать руководство пользователя страница 5

Page | 5

Rack Mounting

The ESP2000 will mount in a standard 19”
rack system. Integral rear mounting rack ears
are also provided for additional support. It is
important that you do not rely on fixing and
mounting the ESP2000 using just the front
panel as the support. Use eight screws and
washers to mount the amplifier to the equipment
rack rails, (four for the fronts and four for the
rear). We recommend using a shock mounted
rack for touring use to prolong the life of your
ESP2000.

Cooling

The ESP2000 has a comprehensive cooling sys-
tem featuring chassis-sealed PCB board mount-
ing and shock mounted, speed controlled fans.
This means that the cooling system never
drives air across PCB boards, connectors or
components ensuring prolonged electronic
component lifespan and minimizing mainte-
nance cycles.

Air is drawn into the front of the amplifier by
the two fans on the rear panel, this passes over
the cooling fins of the heat sinks and exhausts
through the rear. If the heat sink gets too hot,
its sensing circuit will open the output relay,
disconnecting the load.

It is important to have an adequate air supply
at the front of the amplifier, and enough space
around the rear of the amplifier to allow the
cooling air to escape. If the unit is rack-mount-
ed, do not use doors or covers on the rear of
the rack; the exhaust air must flow without
restriction. If you are using racks with closed
backs, use fans on the rear rack panel to
ensure an ample air supply.

AC Power Requirements

The ESP2000 is an advanced power amplifier.
Understanding power distribution, voltage and
current requirements, as well as electrical safety
issues, is critical to the safe operation of the 
ESP2000.

AC Power

The ESP2000 uses a single PowerCon 3-pole
AC main systems with locking connectors to
prevent accidental disconnection. The main AC 
connectors (blue) serve as the power inputs.

The ESP2000 operates in either 115V, 230V or
250V modes. Although pre-configured at the
factory, the unit’s operating voltage mode can
be changed in the field.

Voltage Requirements

The ESP2000 operates safely and without
audio discontinuity if the AC voltage stays with-
in the operating window of 100V÷120V in
115V mode, 205V÷240V when working in 
230V mode and 225÷260V when working in
250V mode at 50 or 60Hz.

CAUTION:

If the On LED does not 

illuminate or the system does not
respond to audio input, remove AC

power immediately. Verify that the voltage is
within the proper range. If the problem persists,
please contact KV2 Audio or an authorized
service center.

If the voltage drops below the low boundary of
its safe operating range, the amplifier will shut
down if the voltage does not rise above the low
boundary before storage circuits are depleted.
How long the amplifier will continue to function
during brownout depends on the amount of
voltage drop and the audio source level during
the drop. If the voltage increases above the
upper boundary of the range, the power supply
can be damaged. 

CAUTION

!

Содержание ESP2000

Страница 1: ...R ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE SERIAL NUMBER WWW KV2AUDIO COM KV2 AUDIO MANUFACTURED IN THE EUROPEAN UNION 2000W 4Ω BRIDGE min 2Ω OUTPUTS OFF ON The future of sound Madeperfectly clear At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to ...

Страница 2: ...ed against defects in material and workmanship Refer to your supplier for more details Service In the unlikely event that your ESP2000 develops a prob lem it must be returned to an authorised distributor service centre or shipped directly to our factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If th...

Страница 3: ...tput Do not connect the ESP2000 output to any other voltage source such as a battery mains source or power supply regardless of whether the ESP2000 is turned on or off 17 Do not run the output of any ESP2000 back into another channels input 18 Refer all servicing to qualified service per sonnel Servicing is required when the amplifier has been damaged in any way such as when the power supply cord ...

Страница 4: ...o channels within a two rack unit chassis It can be used to power any range of passive loudspeakers as well as being specifically designed for opti mised performance with KV2 Audio s ESD Series Whilst this unit is simple to operate improper use can be dangerous This is a very high powered device that can output high voltages and sizeable currents Always use safe operat ing techniques with the ESP2...

Страница 5: ...with closed backs use fans on the rear rack panel to ensure an ample air supply AC Power Requirements The ESP2000 is an advanced power amplifier Understanding power distribution voltage and current requirements as well as electrical safety issues is critical to the safe operation of the ESP2000 AC Power The ESP2000 uses a single PowerCon 3 pole AC main systems with locking connectors to prevent ac...

Страница 6: ...eate inter national or special purpose power connectors Current Requirements Each of the ESP2000 s power supply inputs require approximately 20 Amps max at 115V AC for proper operation This means that both of the ESP2000 s power supplies must be powered from an individual 20 A breaker when running in 115V mode When operating in 230 V mode each of the ESP 2000 s power supply inputs requires approxi...

Страница 7: ... audio cable Reconnect the power cord only after making all signal connections Connect the amplifier to a two pole three wire grounding mains receptacle The receptacle must be connected to a fuse or circuit breaker Connection to any other type of receptacle poses a shock hazard and may violate local electrical codes Do not allow water or any foreign object to get inside the amplifier Do not put ob...

Страница 8: ...ey indicate that the Power Switch is ON and that chan nel of the amplifier is powered up When red they indicate that that channel has overheated and shut down The unit will Auto Reset after it cools down to a safe operating temperature 6 Signal Present Limiter Indicator These are dual colour LED s When green they indicate that signal is present at the Input to that particular channel of the amplif...

Страница 9: ...FER SERVICING TO QUALIFIED PERSONNEL ONLY TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE SERIAL NUMBER WWW KV2AUDIO COM KV2 AUDIO MANUFACTURED IN THE EUROPEAN UNION 2000W 4Ω BRIDGE min 2Ω OUTPUTS OFF ON 1 2 4 3 4 5 NOTE If Bridge Mono is your specific requirement particularly driving subwoofers you may prefer to utilise a KV2 Audio VHD3200 subwoofer a...

Страница 10: ... RMS Out Power 2Ω 1 channel 2 channels loaded 1000W 800W RMS Out Power 16Ω bridged 600W RMS Out Power 8Ω bridged 1000W RMS Out Power 4Ω bridged 1500W RMS Signal Input Input Channels XLR Input Sensitivity 1 55V Input Impedance 20kΩ balanced Signal Output XLR Through Speaker Output Speaker Output Neutrik Speakon 2x Binding posts Features Level Control 0dB Subwoofer Level Control 6dB 60Hz RMS Limiter...

Страница 11: ......

Страница 12: ...o com KVV120080 00 04 0 At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectation ...

Отзывы: