background image

___________________________________________________________________________________________ 

2

 

EB-9V

 

SECTION 1 : FEATURES 

No external battery or DC power supply required, excitation power provided by an internal battery.

Small size, light weight, easy installation, saving labor.

Automatic excitation detection requires no manual operation or settings.

Very low static power consumption, Up to 3 years between battery replacement in standby mode.

Excitation function repeats 3 times and stops automatically when voltage is established.

Battery low voltage alarm reminds user to change battery.

Excitation failure warning, Resets automatically with voltage buildup or when engine stopped.

Battery reverse polarity protection.

Excitation field F+, F- Reverse Polarity Protection.

Manual Forced Excitation Function.

SECTION 2 : SPECIFICATION 

AC Voltage Input

 

Lithium Battery Specifications

 

Voltage 

 300 Vac single-phase 

Model no. 

Ultralife U9VL-J-P 

Frequency 

50/60 Hz 

Voltage 

9 Vdc 

Current 

Normal discharge 700 mA Max 

Excitation Output

 

Pulse discharge 1050 mA Max 

Voltage 

9 Vdc 

Capacity 

1200 mAh @ 23 ˚C 

Power 

700 mA Max.

 

Service Life 

10 years

 

Automatic Flashing Detection 

Environment 

Automatically Outputs Excitation Power When Voltage 

Operating Temperature 

-20 to +6

0 ˚C 

< 10 Vac and Frequency > 40 Hz 

Storage Temperature 

-40 to +60 

˚C 

Relative Humidity 

Max. 95% 

Excitation Time

 

Vibration 

5 Gs @ 60 Hz 

Excitation output 5 seconds, up to three attempts at 

5 second intervals 

Dimensions

 

87.0 (L) x 41.5 (W) x 61.7 (H) mm 

Time Between Battery Change

 

3 years Max. 

Weight

 

( Use only Ultralife U9VL-J-P lithium battery ) 

85 g +/- 2% 

ATTENTION 

1. Before  using  a  Megger  or  a  Withstand  Voltage  Tester,  removes  the  wires  connecting  to  the  EB-9V  to

prevent high voltage damage to the automatic flashing module.

2. Only the original factory ULTRALIFE U9VL-J-P lithium battery should be used for replacement.

3. Use of a standard alkaline battery will reducing the time the unit can operate and the service life of the

battery, could also cause voltage build-up function to fail.