SPECIFICATIONS

Input Power: 230/

115 Volts, 50/60 Hz, 5/10 Amperes

Input Fuse: 

15 Ampere @ 115V; 10 Ampere @ 230V

Output Current: 

Amperes Max  (-12) @ 40 Amperes; (-24) @ 20 Amps

Float Voltage: 

(-12) = 13.25 Volts; (-24) = 26.5 Volts

Remote Sensing: 

Electronic, sense wires not required

Torque: 

DC output connector: 20 in. lbs

LED Status Indicators: 

Power On

Hardware Pack Provided: 

(2) #6 AWG Blue Ferrules, P/N: 091-TERFEB612

Charger Indicators: 

Optional Bar Graph Indicator

Output Waterproof Circuit Breaker (Optional):  
 

(-12): 80 Amperes, P/N: 090-0080-0

 

(-24): 40 Amperes, P/N: 090-0040-0

Output Buss Bar (Optional): 

5 Studs, P/N: 002-3595-5

Weight: 

22 pounds 

OUTLINE 

14.0

9.375

OUTLINE DRAWING

6.25

6

Содержание EURO CHARGER I VHO

Страница 1: ...can using your mobile device for more information 3 YEAR WARRANTY File IM_091 162 XX Rev REV B Revised By PS Date 5 24 26 NOTE This charger is designed for vehicles with dual electrical systems Each b...

Страница 2: ...mbly may result in a risk of electric shock and fire 6 To reduce the risk of electric shock disconnect the charger from the AC source before attempting any maintenance or cleaning 7 LOCATION OF CHARGE...

Страница 3: ...lt or 24Volt battery system Voltage is sensed so that the battery system is charged ac cording to its requirements The total output of the Euro Charger I VHO Battery Charger is 091 162 24 20 Amperes f...

Страница 4: ...tem use ring lugs that have been securely crimped or soldered 7 Verify that the dual voltage switch DV switch on the front pan el corresponds to the applied voltage 8 Wire AC power to input termianl s...

Страница 5: ...CHARGER SHALLCOMPLY WITH UL RECOMMENDATIONS NEC or NFPA STANDARDS 80 Amp Kussmaul Part 090 0080 0 40 Amp Kussmaul Part 090 0040 0 Waterproof Circuit Breaker For model 091 162 12 For model 091 162 24 u...

Страница 6: ...tronic sense wires not required Torque DC output connector 20 in lbs LED Status Indicators Power On Hardware Pack Provided 2 6 AWG Blue Ferrules P N 091 TERFEB612 Charger Indicators Optional Bar Graph...

Страница 7: ...4 Combines switching and circuit breaker function Compact size and surface mount configuration Protects high amperage circuits Latch arms resets breaker after overload Cannot be held in ON position if...

Страница 8: ...arges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kuss maul Electronics Company Inc pr...

Отзывы: