170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
4
WIRING
I. BATTERY CHARGER WIRING INSTRUCTIONS
1.
Refer to the Installation Wiring Diagram I.
2. Battery charger should be installed in a well adequate ventila-
tion.
3. Mount charger using four predrilled holes provided.
4.
Refer to Wiring Specifications to determine the recommended
wire size and maximum lengths. Using a smaller guage may
cause overheating of the terminal. Additional information is
available on request, if longer larger wiring is required.
5. Connect the wiring from the battery system, to the charger out-
put terminal strip.
6. Connect charger wiring the battery system - use ring lugs that
have been securely crimped or soldered.
7.
Verify that the dual voltage switch (DV switch) on the front pan
-
el corresponds to the applied voltage.
8. Wire AC power to input termianl strip.
9. Double check all wiring before applying AC power to input
terminal.
10.
Apply AC power (shoreline power) to input terminal and ob-
serve that the charger is operating. Power On light will illumi-
nate to show that the charger has power.
11.
Verify that the battery voltage appears at the charger output
terminals. A minimum of 6 volts is required to start the charger.
II. WIRING SPECIFICATIONS
** Supplied with wire terminal hardware for 10 foot installation
Length of Wire to Battery
(feet)
0 - 5
< 5 - 10**
< 10 - 20*
Battery Charger Connections
V. BAT +
COM -
V. BAT +
COM -
V. BAT +
8
8
6
6
4
4
Wire Ferrule Used
091-TERFER812
091-TERFEB612
None
* Consult factory if length of wire to battery is longer than 20 feet