background image

INTRODUCTION

The Auto Drain AC system consists of a 120 volt normally open solenoid, a filter and assorted

fittings.   Designed to work with the 120 volt Auto Pump, the solenoid bleeds the filter bowl

when the pump is not running.  As soon as the pressure switch turns on the compressor,

the solenoid is energized and the bleed is closed.  A check valve that is supplied with the

Auto Drain kit must be installed as shown to seal off the vehicles air pressure when the

bleed valve opens.

ITEM

QUANTITY

PART NUMBER

DESCRIPTION

1

1

A2231-1-C108

Solenoid Valve, 120 Volt A.C. normally open

2

1

F5044-02-DH-Z310

Filter with metal bowl

3

1

216P-2

Nipple, 1/8 NPT

4

2

PLB112-4

Nipple, 1/4 NPT Close

5

1

219-P-2

Plug, 1/8 NPT

6

1

219-P-4

Plug, 1/4 NPT

7

1

PL1/4-NIU

Elbow, 1/8 NPT, male - 1/4 tube

8

2

1202P4-4

Street Elbow, 1/4 NPT

9

1

14CVS

Check Valve, 1/4 NPT male -1/4 NPT male

10

1

PLB101-4

Tee, Brass, 1/4 NPT

11

1

NN4-035

1/4 Tubing, 24 inches

12

1

PVC-1/4

Sleeving, 1/4" PVC, 11 inches

AUTO DRAIN COMPONENTS

Содержание 091-9-089

Страница 1: ...6 0857 FAX 631 567 5826 1 YEAR WARRANTY BOOK 091 9 089 inst book Aug 3 2005 KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 AUTO DRAIN AC AN AUTOMATIC MOISTURE DRAIN FOR THE 091 9B 1 AIR COMPRESSOR MODEL 091 9 089 INPUT 120 Volt AC Solenoid ...

Страница 2: ...t be installed as shown to seal off the vehicles air pressure when the bleed valve opens ITEM QUANTITY PARTNUMBER DESCRIPTION 1 1 A2231 1 C108 Solenoid Valve 120 Volt A C normally open 2 1 F5044 02 DH Z310 Filter with metal bowl 3 1 216P 2 Nipple 1 8 NPT 4 2 PLB112 4 Nipple 1 4 NPT Close 5 1 219 P 2 Plug 1 8 NPT 6 1 219 P 4 Plug 1 4 NPT 7 1 PL1 4 NIU Elbow 1 8 NPT male 1 4 tube 8 2 1202P4 4 Street...

Страница 3: ...091 9 089 AUTO DRAIN INSTALLED ON 091 9B 1 AUTO PUMP ...

Страница 4: ...to output terminals of pressure switch These are the same terminals that supply power to the AUTO PUMP motor 3 The AUTO DRAIN is now properly connected Test by bleeding system pressure to start AUTO PUMP and note that when pump shuts down air and moisture will bleed out of drain tube 4 Position drain tube to direct moisture to exterior of vehicle AUTO DRAIN WIRING INSTALLATION ...

Страница 5: ... within 1 year from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the eq...

Отзывы: