Warning!
Never leave the loads unattended, some loads (like a Heater) may cause accidents in such
fire. Nobody wants to return home, finding house surrounded by fire trucks and naughty neigh
-
borhood kids toasting hot dogs against his house
Conformal Coating
The entire line of inverters have been processed with a conformal coating on the PCB, making it
water, rust, and dust resistant.
While these units are designed to withstand corrosion from the salty air, they are not splash proof
INSTALLATION
I. Location
Follow all the local regulations to install the inverter.
Please install the equipment in a location of Dry, Clean, Cool with good ventilation.
Working temperature: -20°C to 45°C (-4°F to 113°F)
Storage temperature: - 40°C to 70°C (-40°F to 158°F )
Relative Humidity: 0% to 95% , non-condensing
Cooling: Forced air
Warning! Operation in a condensing environment will invalid warranty.
II. DC Wiring Recommendations
It is suggested the battery bank be kept as close as possible to the inverter. The following table is
a suggested wiring option for DC cable with length from 1 to 15 ft.
Battery cables must have crimped (or preferably, soldered and crimped) copper compression
lugs unless aluminum mechanical lugs are used. Soldered connections alone are not acceptable.
High quality, UL-listed battery cables are available.These cables are color-coded with pressure
crimped, sealed ring terminals.
21
091-263-12-1500_GEN1
Length of Wire to Battery (feet)
Battery Charger Connections
V.
B
AT
+
V.
B
AT
-
V.
B
AT
+
V.
B
AT
-
V.
B
AT
+
V.
B
AT
-
Wire # Gauge (awg)
2
2
2
2
00
00
Fuse
0 - 5 (5% Vdrop)
5 - 10 (5% Vdrop) 10 - 15* (5% Vdrop)
* Consult factory if length of wire to battery is longer than 20 feet
200A
200A
400A
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826