background image

 

 

 

DESCRIPTION 

 

The instructions in this manual contain important information on the safe mounting, usage, cleaning and maintenance of 
the  device.  Thus,  keep  the  manual  at  a  place  easily  accessible  by  the  person  who  will  use  the  machine,  and  the 
technician. 

 

Mounting,  conversions  for  different  gas  groups  or  electrical  inlet,  and  maintenance  works  of  the  device  should  be 
performed  by  a  specialist  authorized  in  this  subject  and  in  accordance  with  the  instructions  of  the  manufacturer 
company. 

 

Gas and electrical connections of the device should be arranged according to the tables and electrical diagram given in 
this manual. 

 

Manufacturer company accepts no responsibility for the final damages incurred in humans or properties that are caused 
by  any  procedure  not  conforming  to  the  instruction  manual,  or  maintenance  or  technical  interventions  that  are  not 
performed by authorized people. 
 

 

MOUNTING INSTRUCTIONS 

Placement

 

 

Place  the  device  beneath  a  filtered  exhaust  hood  in  order  to  eliminate  smell  and  fume  that  may  be  emitted  during 
cooking. 

 

Place the device at a place min. 10cm away from the side or back wall to prevent excessive temperature rises.   

 

Remove  the  nylon  protection  cover  on the  device.  If  there  are  any  adhesive  residues left  on  the  surface, clean  with  a 
suitable solvent. 

 

Balance the device by adjusting its four adjustable legs on a suitable ground.fig.A 

 

Mount the pan lifting arm. 

 

Gas Connection

 

 

Connection to the gas installation should be made with flex pipe and ball valve. Fix the said ball valve to a place that is 
away from heat and easily accessible in case of a danger. 

 

Gas connection must be done according to national and local gas standarts . 

 

Gas inlet is indicated by GAS label on the appliance body 

 

After all connections are completed, check for gas leakage at joints through leakage detection device or soapy water. 

 

Check whether the device is suitable for connected gas type. If not, see “Conversion to Different Gas Types”  
 

ATTENTION:

 

All adjustments and modifications to be performed on the 

gas installation and connection of the device should be performed by 
authorized people.

 

 

 

Water connection

 

 

Connect the water inlet to the water supply through a tap. 

 

Mount a mechanical filter on the water inlet of the device and the dirt and metal particles that may intrude in the device 
will be prevented through that filter. 

 

Before  connecting  the  last  pipe  part  to  the  machine,  clean  the  accumulated  dirt  by  discharging  some  water  and  then 
complete the connection. 

 

Check whether there is any leakage at the joints. 
 

Electrical Connection

 

 

Connect the device to a proper network according to the electrical installation standards of the relevant country. 

 

Feed the device with suitable network voltage written on the information plate. 

 

Connect to the electrical installation over a suitable automatic fuse. Fix the said fuse on a place that is easily accessible 
in case of a danger. 

 

The  cable  connecting  the  device  to  the  electrical  installation  should  be  at  least  of  H05  RNF  quality  and  its  section 
should be selected to be sufficient to carry the maximum current. 

 

It is recommended to include a leakage current fuse in the feeding installation. 

 

Voltage tolerance should not exceed ± 10%. 

 

If the device will be used in a commercial kitchen, apply a correct grounding system. Here, consider DIN VDE D100 
Article 540. 

 

The device must be grounded. Grounding point is marked with " 

 ". 

 

Содержание G7TD200G

Страница 1: ...INSTRUCTION AND MAINTENANCE MANUAL TILTING BRATT PAN GAS Professionally with Professionals ...

Страница 2: ...r Gas connection must be done according to national and local gas standarts Gas inlet is indicated by GAS label on the appliance body After all connections are completed check for gas leakage at joints through leakage detection device or soapy water Check whether the device is suitable for connected gas type If not see Conversion to Different Gas Types ATTENTION All adjustments and modifications t...

Страница 3: ...ork Turn the gas control button 5 to position Pilot burner ignition 7 and push down At the same time press down the piezoelectric ignition button as well So the spark needed for pilot burner flame is produced Release gas control button approximately after 20 seconds Pilot burner flame will continue to burn If does not burn repeat ignition process again Ignition may be checked through flame observa...

Страница 4: ...nd switches off burners CLEANING and MAINTENANCE Do not wash the device with high pressurized water You must switch off the gas and electrical connection of the device before starting to cleaning or maintenance activities Before it cools down completely wipe the device with a cloth immersed in warm soapy water at the end of each working day During cleaning the device surface do not use corrosive m...

Страница 5: ...D200G G7TD200G 900 900 800 GAZ GİRİŞ GAS INLET 646 634 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET ELEKTRİK GİRİŞ ELECTRICAL INLET 261 321 SU GİRİŞ WATER INLET SU GİRİŞ WATER INLET 122 150 750 G9TD200G UDFB980G 900 900 1200 523 634 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET 261 321 SU GİRİŞ WATER INLET 523 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET SU GİRİŞ WATER INLET 12...

Страница 6: ... DEPTH mm 730 900 900 HEIGHT mm 900 900 900 HEAT CAPACITY KW 18 20 30 PAN CAPACITY Lt 60 80 120 GAS INLET Inch 1 2 1 2 1 2 ELECTRICAL INLET V 220 230V 50 60Hz 220 230V 50 60Hz 220 230V 50 60Hz WATER INLET Inch 1 2 1 2 1 2 GROSS WEIGHT kg 130 145 220 Fig A ...

Страница 7: ...3 1 Şekil B Figure B 4 2 Figure B ...

Страница 8: ...Şekil C Figure C 5 6 7 8 9 10 11 12 13 Fig C ...