17
.
ºC
Test Voltage
SELECT
RANGE
ZERO
HOLD
H
LOCK
REC
INSULATION
R
TEST
Hz
Temp mA
Hz
mV
200mA
W
V
HzV
VFD
OFF
INSULATION
50V...1000V
200mA
INS.
–
mA
INS.
+
Temp
JACK
W
V
COM
HBC FUSED
(0.25A)
HBC FUSED
MAX 0.6A
1000V CAT III
MAX
600V CAT IV
INSULATION
–
+
Temp
–
+
+
–
+
–
ºF
.
ºF
+
–
+
–
1
Test Voltage
SELECT
RANGE
ZERO
HOLD
H
LOCK
REC
INSULATION
R
TEST
Hz
Temp mA
Hz
mV
200mA
W
V
HzV
VFD
OFF
INSULATION
50V...1000V
200mA
INS.
–
mA
INS.
+
Temp
JACK
W
V
COM
HBC FUSED
(0.25A)
HBC FUSED
MAX 0.6A
1000V CAT III
MAX
600V CAT IV
INSULATION
–
+
SELECT
–
+
Note :
Be sure to insert the banana plug type-K temperature bead
probe Bkp60 with correct
+ –
polarities. You can also use a plug
adapter Bkb32 (Optional purchase) with banana pins to type-K
socket to adapt other standard type-K mini plug temperature
probes.
+Hz
DCmA, ACmA functions
:
Press the
SELECT
button momentarily to toggle the subject
functions. Last selection will be saved as power up default for
repeat measurement convenience.
Temperature functions
:
Press
SELECT
button momentarily to toggle ºC and ºF readings.
Last selection will be saved as power up default for repeat
measurement convenience.
®
18
HzV
OFF
VFD
AUTO
0
6
m
Test Voltage
SELECT
RANGE
ZERO
HOLD
H
LOCK
.
REC
INSULATION
R
TEST
Hz
Temp mA
Hz
mV
200mA
INSULATION
50V...1000V
A
Hz
Hz
mA
.
W
V
200mA
INS.
–
mA
INS.
+
Temp
JACK
W
V
COM
HBC FUSED
(0.25A)
HBC FUSED
MAX 0.6A
1000V CAT III
MAX
600V CAT IV
INSULATION
–
+
–
+
mA
Hz
HzV
OFF
VFD
AUTO
0
6
m
Test Voltage
SELECT
RANGE
ZERO
HOLD
H
LOCK
.
REC
INSULATION
R
TEST
Hz
Temp mA
Hz
mV
200mA
INSULATION
50V...1000V
A
mA
W
V
200mA
INS.
–
mA
INS.
+
Temp
JACK
W
V
COM
HBC FUSED
(0.25A)
HBC FUSED
MAX 0.6A
1000V CAT III
MAX
600V CAT IV
INSULATION
–
+
–
+
SELECT
1
Earth Continuity Test Function
:
This function measures the
Resistance values of earth
connection & equipotential
bonding in Low Voltage
Distribution Systems upto
Nominal Voltage (Un)830V,
Phase-to-phase. DO NOT use
on Systems with Nominal
V o l t a g e s a b o v e t h a t .
Measurements shall only be
carried out on de-energized
circuits.
TEST
The LCD icon used alone throughout in this manual is referred
as active measurements of Earth Continuity Test Function through
the activation of the
TEST
button on the meter or on the Remote
Probe. Check the fuse before each . If the fuse is open, the
meter will display
“OPEn”
when the is being activated at no
circuit connection to the probes. Refer to the maintenance section
for fuse replacement.
is inhibited when the meter beeps and displays
“>2V”
plus
warning against energized circuit of more than 2V is being
connected, before the is active. Connecting to energized
circuits when the is active will produce false results & may
blow the protection fuse and / or damage the instrument. Always
check with voltage function & remove power from the circuits
before carrying out the .
TEST
TEST
TEST
The measuring loop is protected by an HBC 1KV F fuse against
accidental extraneous overvoltages.
TEST
TEST
TEST