TYPE-K TEMPERATURE
RANGE
ACCURACY*
-20°C ~ 300°C
*Type-K Thermocouple range & accuracy not
included.
-4°F ~ 572°F
2% + 3°C
2% + 6°F
Accuracies assume meter interior and the ambient
have reached the same temperature (isothermal
stage) for a correct junction voltage compensation.
Allow enough settling time for a significant change
of ambient temperature. It can take up to an hour
for changes > 5°C.
09
AUDIBLE CONTINUITY TESTER
between 10
and 120
Audible Threshold
MAX HOLD (Voltage & Current)
Specified accuracy ± 50 digits
for changes >25ms in duration
DIODE TESTER
Test Current (Typical)
<1.6V DC
0.25mA
Open Circuit Voltage
10
1) 3-3/4 digits 4000 counts
LCD display
2) Push-buttons for special
functions & features
3) Selector to turn the
Power On or Off and
select a function
4) Input Jack (+) for 10A
(20A for 30sec) current
function
5) Input Jack (+) for all
functions EXCEPT
current (
A, mA, A)
function
6) Common (Ground
reference) Input Jack(-)
for all functions
7) Input Jack (+) for milli-
amp and micro-amp
functions
V. PRODUCT DESCRIPTION :
This user's manual uses only representative model for illustrations.