4
KUSAM-MECO April 2011
®
3. INTERNATIONAL ELECTRICAL SYMBOLS
AC--Alternating Current
DC--Direct Current
Earth (Ground)
Double Insulation or Reinforced insulation
Fuse.
Caution ! Risk of electric shock
Caution ! Refer to the explanation in this
Manual.
7
~
?
?
5msCREST-MAX capture mode
(Peak Hold)
?
Autoranging Relative -Zero mode
?
?
EF-Detection (NCV)
?
Beep-Jack input warning
?
Hz Line Level Frequency
?
Hz Logic Level Frequency
?
Diode Test & Continuity Test
VFD-V & VFD-Hz in Dual Display
Display Hold
4) SPECIAL FEATURES
:
5
KUSAM-MECO April 2011
®
5) GENERAL SPECIFICATIONS
?
Display :
3-5/6 digits 6000 3 digits 999 counts
dual display LCD.
?
Polarity :
Automatic
?
Update Rate
: 5 per second nominal;
?
Operating Temperature :
0°C to 40°C
?
Pollution degree :
2
?
Altitude :
Operating below 2000m
?
Relative Humidity :
Maximum relative humidity 80% for
temperature up to 31°C decreasing linearly to
50% relative humidity at 40°C
?
Storage Temperature :
-20°C to 60°C,<80%R.H.(with battery removed)
?
Temperature Coefficient (T.C.) :
Nominal 0.15 x (specified accuracy) / °C @
(0°C--18°C or 28°C--40°C) or otherwise
specified.
?
Sensing :
Average sensing.
?
Transient Protections :
6kV(1.2/50
m
s surge)
?
Safety :
Double insulation per IEC61010-1
nd
nd
2 Ed., EN61010-1 2 Ed., UL61010-1 2nd Ed.
& CAN/CSA C22.2 No.61010.1-0.92 to CAT II
1000V, CAT III 600V and CAT IV 300V AC & DC
?
Power consumption :
5.4mA typical
?
Low battery :
Below approx. 2.4V
?
APO Timing :
Idle for 34 minutes
?
APO Consumption :
10µA typical