II  TECHNICAL FEATURES

 

Measurement display  :

 Displays 4 digit LCD

  

Measuring range          :

 0~25% (VOL)

  

Resolution                    :

 0.1% (VOL)

  

Measurement error      :

 ±0.5%

  

Over measurement range display :

 “OL”

  

Alarming method         :

 acousto-optic alarming

  

Working principle of the sensor :

 

                                            source cell sensor

  

The service life of the sensor :

 2 years 

                                            (it can then be replaced)

  

Operation temperature:

  -10°C~40°C(14°F~104°F)

  

Storing temperature     :

 0°C~30°C (32°F~86°F)

  

Operating humidity      :

 0~99% RH

                                            (relative humidity)

  

Storing humidity          :

 20%~80% RH

                                            (relative humidity)

  

Power supply                :

 3x1.5VAAA

                                            alkaline batteries

  

Batteries service life    : 

about 100 hours of 

   continuous use (when the backlight is off).

  

Dimension                      :

 172 x 51 x 26 (mm)

  

Weight                            :

 

2

3

III  PRODUCT DESCRIPTION

1.  MODE ON :

 Press 

 

& hold for 2s to enable it

2.  Position shifting button (   )
3.   Digit (0-9) adjust button (   )

4.  MODE OFF : 

Press & hold for 2s to disable it

5.  The first alarm (AL1) (yellow indicator)
6.  The second alarm (AL2) (red indicator)
7.  Buzzer
8.  Display
9.  Sensor
10.Battery

 

compartment cover 

 

(push the cover 

     

downwards to open it)

OFF AL1

AL2

O Alarm

2

Deterctor

MODE

ON

%Vol.

SCAN

888.8

ALA1 ALA2

KM 5490

7

4

5

6

1

2

8

3

9

10

Содержание KM 5490

Страница 1: ...lation Resistance Testers Earth Resistance Testers Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Paper Grain Moisture Meter Distance Meter Digital Hand Held Temperature Indicators Digital Lux Meter Power Factor Regulator Maximum Demand Controller Digital Power Meter Gas ...

Страница 2: ...ogy design and has multiple functions With highlight backlight display and acousto optic alarming it is easily configured The in built temperature compensation makes the meter measure the correct value of oxygen in the environment temperature of 10 40 C As its case is ergonomically designed it looks elegant and is easy to carry The product features Oxygen manufacturing factory Petroleum refining a...

Страница 3: ...midity Storing humidity 20 80 RH relative humidity Power supply 3x1 5VAAA alkaline batteries Batteries service life about 100 hours of continuous use when the backlight is off Dimension 172 x 51 x 26 mm Weight 2 3 III PRODUCT DESCRIPTION 1 MODE ON Press hold for 2s to enable it 2 Position shifting button 3 Digit 0 9 adjust button 4 MODE OFF Press hold for 2s to disable it 5 The first alarm AL1 yel...

Страница 4: ...e alarms for the meter Switch the meter to the preset status of the level I alarm by slightly pressing the MODE ON button when the meter is in the SCAN mode and the ALA1 is shown on the display Press the Position Shift button and digit adjusting button 0 9 to set up the data of the level I alarm if you press the MODE ON button now you would exit the setting mode of level I alarm and enter into the...

Страница 5: ...his meter is a precise measurement apparatus To avoid damaging the meter keep it away from water and hot objects more than 60 C 2 If the meter will be measuring for a long time please turn off the backlight to save power consumption and prolong the service life of the battery 3 When is displayed the battery is fully charged the small black frame in the battery sign reduces as the battery power val...

Страница 6: ...annot be Moved properly 10 14 Person may be tired and lose attention 6 10 Person may be dizzy nauseas lose consciousness and go into a coma Less than 6 Person may stop breathing and die 9 MUMBAI TEST CERTIFICATE OXYGEN ANALYSER This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications The instrument has been calibrated by using ...

Страница 7: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product which is returned to a KUSAM MECO authorized service center within the warranty period 11 G 17 Bharat Indus...

Отзывы: