2.6 Diode Test

Test current

< 1.2mA

Open circuit voltage

< 3.2V

Overload Protection

500V DC/rms AC

Application

Display reading approx. 
Diode forward voltage value

Relative Humidity 

max. 80%

2.7 FREQUENCY

Range

Accuracy

1Hz-2KHz

±(2.0%rdg+5d) 

2.8 Function Characteristics

Measurement method

Dual slope integration technical

Reading Rate

3 reading/Sec.

Polarity

Automatic, indicated minus 
assumed plus.

Overload indication

Blanking of all digits. Except 
MSD. decimal point and 
sign.appropriate

Power requirements

9V Battery

Battery life

Up to 200 hours typical with 
Alkaline Up to 150 hours typical 
with Zinc carbon 

Display

LCD 31/2 digit (1999 count) 
0.5" high

®

06

3.1 DC/AC VOLTAGE MEASUREMENT

3.1.1 Connect red test lead to "+' ;Black test lead to "COW. 
3.1.2 Set RANGE switch to ACV or DCV desired position. 
3.1.3 Connect test leads to device or circuit being tested. 
3.1.4 Read voltage value on Digital Display.

3.2 AC Current Measurement

3.2.1 Set Function/Range Switch to the ACA 1000A range, 
if the display indicates one or more leading zeros, shift to the 
200A or 20A range to improve the resolution of the 
measurements.

3.2.3 Press the trigger to open the transformer jaws and 
clamp one conductor only. It is impossible to make 
measurements when two or three conductors(wires) are 
clamped at the same time.

3.2.4 Display reading is the AC current flowing through the 
conductor

3.2.5 Press the trigger to open the transformer jaws and 
remove clamp meter from the conductor.

3.3 Diode Tests

3.3.1 Connect the red test lead to the "VG" jack and the 
black test lead to the "COM" jack.

3.3.2 Set Function /Range Switch to the diode test position.

3.3.3 Turn off power to the circuit under test.

3.3.4 Read the forward voltage value on digital display. 

3.3.5 Reverse probes. If the diode is good. "1" is displayed. 
If the diode is shorted, ".000" or another number is displayed.

3.3.6 If the diode is open circuit, "1" will be displayed in both 
directions of the diode.

Содержание KM 3060

Страница 1: ...New catlog 2015 new arrival catalogs KM 3060 cdr 1000A AC DIGITAL CLAMPMETER ELECTRICAL SPECIFICATIONS KM 3060 AC CURRENT Range Overload Protection 1200A within 60 seconds 20 A 200 A 50Hz 60Hz 1000 A Accuracy Resolution 3 rdg 5dgts 0 01 mA 2 rdg 5dgts 0 1 mA 2 rdg 5dgts for 800A below 3 rdg 5dgts for others current 1 A AC VOLTAGE Range Overload Protection 750V AC DC on all ranges Input Impedance 9...

Страница 2: ...er Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insulation Resistance Testers ...

Страница 3: ...neglected contaminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective pr...

Страница 4: ...1200A within 60 seconds Jaw opening 2 5cm Instruction Manual This meter is completely portable LCD 31 2 digit clamp meter Designed for use by electricians technicians serviceman It s rugged structure design is good feeling to hold in operator s hand and convenient to use 08 TEST CERTIFICATE This Test Certificate warrantees that the product has been inspected and tested in accordance with the publi...

Страница 5: ...or continuity position 3 4 2 Turn off the power from the circuit under test 3 4 3 Connect the red test lead to the VGA jack and the black test lead to the COM jack 3 4 4 Touch the probes to the test points In ohms the value indicated in the display is the measured value of resistance In continuity test the beeper sounds continuously if the resistance is less than 50G 3 5 FREQUENCY Measurement 3 5 ...

Страница 6: ...voltage value on Digital Display 3 2 AC Current Measurement 3 2 1 Set Function Range Switch to the ACA 1000A range if the display indicates one or more leading zeros shift to the 200A or 20A range to improve the resolution of the measurements 3 2 3 Press the trigger to open the transformer jaws and clamp one conductor only It is impossible to make measurements when two or three conductors wires ar...

Страница 7: ...ty over range and LO BAT indicators 4 Data Hold Switch A push switch Push ON Push OFF do not pull to select function Push ON to hold the measured value and store the value in memory_ Push OFF to release hold function A rotary switch is used to select measurement Function and Range switch 5 Rotary Switch 05 6 connector High input terminal for voltage resistance continuity measurement Accept banana ...

Отзывы: