background image

MODEL -  KM 2778 

                  

OPERATION MANUAL

AN ISO 9001:2015 COMPANY

17, Bharat Industrial Estate, T. J. Road, Sewree (W),

 Mumbai-400015. INDIA

Tel.: 022-24156638, 27754546, 24124540, 24181649  

E-mail : 

  [email protected]

[email protected];

Website :

 www.kusamelectrical.com

LIST OF PRODUCTS

*  

Digital Multimeter                     

*  

Digital AC & AC/DC Clampmeter

*  

AC Clamp Adaptor                  

*  

AC/DC Current Adaptor

*  

Thermo Anemometer               

*  

Thermo Hygrometer

*  

Distance Meter                        

*  

Digital Lux Meter

*  

Network Cable Tester              

*  

Power Factor Regulator

*  

Earth Resistance Tester           

*  

Digital Panel Meters

*  

DC Power Supplies                 

*  

High Voltage Detector

*  

Calibrators                               

*  

Gas Analysers

*  

Frequency Counter                  

*  

Function Generator

*  

Phasing Sticks                         

*  

Battery Tester

*  

Waterproof Pen Testers           

*  

Solar Power Meter

*  

EMF Detector

*  

Wood, Paper & Grain Moisture Meter

*  

Transistorised Electronic Analog & Digital Insulation   

    

Resistance Testers(upto 10 KV)

*  

Digital Sound Level Meter & Sound Level Calibrator

*  

Digital contact & Non-contact Type Tachometer

*  

Digital Non-contact (infrared) Thermometer

*  

Maximum Demand Controller/Digital Power Meter

*  

Digital Hand Held Temperature Indicators

®

®

®

®

AC / DC Clamp-On 

Multimeter with VFD, 

EF-Detection, PC Interface &

Extended 1500V DC Range

13/11/2018

Содержание KM 2778

Страница 1: ...Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Tester...

Страница 2: ...ce Extended 1500V DC Range SAFETY 01 TERMS IN THIS MANUAL 02 INTERNATIONAL ELECTRICAL SYMBOL 03 FEATURES GENERAL SPECIFICATION 04 ELECTRICAL SPECIFICATION 06 PRODUCT DESCRIPTION 14 OPERATION 15 MAINTE...

Страница 3: ...uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible 02...

Страница 4: ...C Relative Humidity Maximum 80 R H for temperature upto o o 31 C decreasing linearly to 50 Relative Humidity at 40 C o o Storage Temperature 20 C to 60 C 80 R H With battery removed Altitude Operatin...

Страница 5: ...onsumption Typical 14mA for Current function 5 2mA for others APO Timing Idle for 34 minutes APO Consumption 10 A typical Dimension 264 L x 97 W x 43 H mm Weight Approx 608gm Accessories Test leads pa...

Страница 6: ...2 Accuracy Resolution Range True RMS Crest Factor 1 4 1 at full scale 2 8 1 at half scale 1 Induced error from adjacent current carrying conductor 0 1A A 2 Specified with Relative Zero mode applied to...

Страница 7: ...0 00 F 2 3 5 rdg 5dgts Resolution Range 2 4 0 rdg 5dgts 1 Accuracy 600 0 F 2000 F 1 Accuracies with film capacitor or better 2 Temperature Coefficient 0 25 x specified accuracy C 0 C 18 C or 28 C 40 C...

Страница 8: ...DC typical Open Circuit Voltage Accuracy 1 0 3d 11 TM AUTOCHECK _DCV Accuracy Resolution Range TM AutoCheck Lo Z DCV Threshold 1 5VDC 1 5VDC nominal TM AutoCheck Lo Z DCV input impedance Initially app...

Страница 9: ...pick up 9 Jaw center DCA polarity Indicator at where best DCA ACA accuracy is specified 8 Jaw trigger for opening the clamp jaw 13 6 000 V 1 5 rdg 5dgts 60 00 V 600 0 V 1000 V 1 Accuracy Resolution Ra...

Страница 10: ...users of being in such low impedance mode Peak initial load current while probing 1000VAC for example can be up to 566mA 1000V x 1 414 2 5k decreasing abruptly to approx 3 37mA 1000V x 1 414 420k TM w...

Страница 11: ...ble Frequency Device signals It however further pre selects the most appropriate voltage ranges and thus the Hz trigger levels to best cope with most VFD Voltage and VFD Frequency applications Note Th...

Страница 12: ...apacitance function in a live circuit will produce false results and may damage the meter In many cases the suspected component s must be disconnected from the circuit to obtain an accurate measuremen...

Страница 13: ...through the test leads terminals Be sure to insert the banana plug type K temperature bead probe Bkp60 with correct polarities You can also use a plug adapter bkb32 optional purchase with banana pins...

Страница 14: ...ature freezes the display for later view Press the HOLD button momentarily and release to toggle the hold feature PC computer interface capabilities Hold Press CREST HOLD button for one second or more...

Страница 15: ...e resistance input terminal has subjected to high voltage transient caused by lightning or switching surge to the system under test by accident or abnormal conditions of operation the protective imped...

Страница 16: ...78 The meter uses standard 1 5V AA Size IEC LR6 battery X 2 Loosen the 2 captive screws from the battery cover case Lift the battery cover case Replace the batteries Replace battery cover case Re fast...

Страница 17: ...ected contaminated or damaged by accident or abnormal conditions of operation or handling All transaction are subject to Mumbai Jurisdiction KUSAM MECO authorized dealer shall extend this warranty on...