Periodically wipe the case with a damp cloth and mild detergent; do 
not  use  abrasives  or  solvents.  If  the  meter  is  not  to  be  used  for 
periods of longer than 30 days, remove the batteries and store them
separately.

Cleaning and Storage :

Battery replacement :

The meter uses standard 1.5V AAA Size (IEC R03) battery X 2.
Loosen  the  2  captive  screws  from  the  battery  cover  case.  Lift  the
battery  cover  case.  Replace  the batteries.  Replace battery cover 
case. Re-fasten the screws.

This  Clamp-on  meter  is  designed  to  apply  around  or  remove  from
uninsulated  hazardous  live conductors. But still, individual protective
equipment  must  be  used  if  hazardous  live  parts  in  the  installation 
where measurement is to be carried out could be accessible.

CAUTION :

Disconnect  the test leads from the test points before changing meter
functions.

II. INTERNATIONAL ELECTRICAL SYMBOLS :

III. CENELEC Directives :

The instruments conform to CENELEC Low-voltage directive 2006/

95/EC and Electromagnetic compatibility directive 2004/108/EC &

RoHS directive 2011/65/EU.

Caution ! Refer to the explanation in this Manual.

Caution ! Risk of electric shock.

Earth (Ground)

Double Insulation or Reinforced insulation

Fuse

AC--Alternating Current

DC--Direct Current

Three-phase Alternating Current

conductors is permitted.

Application around and removal from hazardous live

3

Содержание KM 175D

Страница 1: ...rature 20 C 60 C 80 R H with battery removed o o o o o Temperature Coefficient Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Battery x...

Страница 2: ...52 F 1 0 0 8 C Accuracy1 2 1 0 1 C 1 0 1 5 F 1 0 2 F 1 2 K type thermocouple range accuracy not included Accuracies assume meter interior has the same temperature of the ambient isothermal stage for a...

Страница 3: ...ometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequ...

Страница 4: ...dent or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a gre...

Страница 5: ...WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use Keep your hands fingers behind the hand finger barriers o...

Страница 6: ...ve conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test...

Страница 7: ...range Backlighted LCD display Duo Core to simultaneously measure clamp on Amps A DMM functions VFD V Hz for fundamental V Hz of most Variable Frequency Drives Display Hold Non Contact EF Detection NC...

Страница 8: ...abled automatically in this mode Hold feature freezes the display for later view LCD turns on Press the HOLD button momentarily to toggle the hold feature The Complementary Beeper feature can be selec...

Страница 9: ...lead terminals COM Application Notes on Flame Sensors The DCmA function is designed especially for HVAC R flame sensor applications The 0 1 mA resolution is useful for identifying the minute current...

Страница 10: ...nt 0 60A kV 50 60Hz 3 Specified accuracy is for measurements made at the jaw center When the conductor is not positioned at the jaw center add 2 to specified accuracy for position errors 4 Induced non...

Страница 11: ...must be disconnected from the circuit to obtain an accurate measurement reading Capacitance Diode functions Inputs are made through the test lead terminals COM Defaults at Capacitance Press SELECT bu...

Страница 12: ...from 2 of range CAUTION Using Resistance Continuity function in a live circuit will produce false results and may damage the meter In many cases the suspected component s must be disconnected from the...

Страница 13: ...0 W W Response Time 32ms approx 3 000 V 1 5 rdg 5dgts DIODE TESTER Accuracy Resolution Range 1 mV Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typical Non Contact EF Detection NCV An anten...

Страница 14: ...00V CAT III 300V CAT IV V W Hz EF V OFF AUTO H P RMS 8 8 8 8 mFA V VFD P RMS SELECT HOLD COM CAT III 600V CAT IV 300V 2 3 1 4 6 10 mA A AUTO kW Hz 6 1 7 5 Duo The detected Electric Field strength is i...

Страница 15: ...much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Adjacent current carrying devices such as transformers motors an...

Отзывы: