Kusam-meco KM 175D Скачать руководство пользователя страница 3

®

®

AN ISO 9001:2008 COMPANY

MODEL - KM 175D

AC TRUE RMS

DUAL DISPLAY 

DIGITAL CLAMPMETER

OPERATION MANUAL

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649. 

Fax :

 (022) 24149659

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

              www.kusam-meco.co.in

®

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

Содержание KM 175D

Страница 1: ...rature 20 C 60 C 80 R H with battery removed o o o o o Temperature Coefficient Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Battery x...

Страница 2: ...52 F 1 0 0 8 C Accuracy1 2 1 0 1 C 1 0 1 5 F 1 0 2 F 1 2 K type thermocouple range accuracy not included Accuracies assume meter interior has the same temperature of the ambient isothermal stage for a...

Страница 3: ...ometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequ...

Страница 4: ...dent or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a gre...

Страница 5: ...WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use Keep your hands fingers behind the hand finger barriers o...

Страница 6: ...ve conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test...

Страница 7: ...range Backlighted LCD display Duo Core to simultaneously measure clamp on Amps A DMM functions VFD V Hz for fundamental V Hz of most Variable Frequency Drives Display Hold Non Contact EF Detection NC...

Страница 8: ...abled automatically in this mode Hold feature freezes the display for later view LCD turns on Press the HOLD button momentarily to toggle the hold feature The Complementary Beeper feature can be selec...

Страница 9: ...lead terminals COM Application Notes on Flame Sensors The DCmA function is designed especially for HVAC R flame sensor applications The 0 1 mA resolution is useful for identifying the minute current...

Страница 10: ...nt 0 60A kV 50 60Hz 3 Specified accuracy is for measurements made at the jaw center When the conductor is not positioned at the jaw center add 2 to specified accuracy for position errors 4 Induced non...

Страница 11: ...must be disconnected from the circuit to obtain an accurate measurement reading Capacitance Diode functions Inputs are made through the test lead terminals COM Defaults at Capacitance Press SELECT bu...

Страница 12: ...from 2 of range CAUTION Using Resistance Continuity function in a live circuit will produce false results and may damage the meter In many cases the suspected component s must be disconnected from the...

Страница 13: ...0 W W Response Time 32ms approx 3 000 V 1 5 rdg 5dgts DIODE TESTER Accuracy Resolution Range 1 mV Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typical Non Contact EF Detection NCV An anten...

Страница 14: ...00V CAT III 300V CAT IV V W Hz EF V OFF AUTO H P RMS 8 8 8 8 mFA V VFD P RMS SELECT HOLD COM CAT III 600V CAT IV 300V 2 3 1 4 6 10 mA A AUTO kW Hz 6 1 7 5 Duo The detected Electric Field strength is i...

Страница 15: ...much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Adjacent current carrying devices such as transformers motors an...

Отзывы: